Speaker Output Low

 

Symptom

Diagnosis

Remedy

 

 

 

 

O

 

 

 

 

 

 

TROUBLE-S

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

I

 

 

 

 

 

 

 

 

 

Speaker Output Low

Input gain(s) for amplifier incorrectly

Readjust input gains of amplifier.

 

 

 

 

N

 

 

 

 

 

G

 

or Distorted

set.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Source unit output too low or source

Check system with known working

 

 

 

 

 

unit has no output.

source and repair or replace original

 

 

 

 

 

 

source as needed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase selection of amplifier incorrectly

Check speaker polarity and phase switch

 

 

 

 

 

selected or speakers wired out of polar-

position and correct as needed.

 

 

 

 

 

 

 

 

ity from the left to right channel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XCards are missing or not placed prop-

Check crossover switches and XCard

 

 

 

 

 

erly in crossover slots and/or switches

positions and repair or replace as nec-

 

 

 

 

 

are not properly selected.

essary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low battery voltage or large voltage

Check the alternator, battery, fuse or

 

 

 

 

 

drops to the amplifier under load.

circuit breaker and power and ground

 

 

 

 

 

 

wiring and repair as necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amplifier Noise

Voltage spike from output of preceding

Disconnect input signal to amplifier

 

 

 

(Turn-on Pop)

component is entering amplifier

and turn amplifier on and off. If noise is

 

 

 

 

 

through input signal.

eliminated, connect REM lead of am-

 

 

 

 

 

 

plifier to source unit with a delay turn-

 

 

 

 

 

 

on module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage spike from remote turn-on lead

Use different 12 volt source for REM

 

 

 

 

 

is entering through REM input termi-

lead of amplifier (i.e., battery direct). If

 

 

 

 

 

nal.

noise is eliminated, use relay to isolate

 

 

 

 

 

 

amplifier from noise turn-on output.

 

 

 

 

 

 

 

 

 

 

 

No output from Pass-Thru

RCA Input from source unit is not con-

Check connections, substitute

with

 

 

 

output of amplifier.

nected or not functioning properly.

known working source and cables and

 

 

 

 

 

 

repair or replace as necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When using the BLT, Balanced Line

Check connections, substitute

with

 

 

 

 

 

Input from BLT is not connected or not

known working BLT and cables and

 

 

 

 

 

functioning properly.

repair or replace as necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unbalanced/Balanced Line switch is

Check switch position and correct as

 

 

 

 

 

not selected for corresponding input.

necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XCards are missing or not placed prop-

Check crossover switches and XCard

 

 

 

 

 

erly in crossover slots.

positions and repair or replace as nec-

 

 

 

 

 

 

essary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 42 –