Rockford Fosgate 250.1 manual Symptom, Diagnosis, Remedy, Low or distorted output from, amplifier

Models: 250.1

1 62
Download 62 pages 41.7 Kb
Page 46
Image 46
Low or distorted output from

Symptom

Diagnosis

Remedy

 

 

 

 

 

 

 

H

 

 

 

 

 

TROUBLE-S

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

T

Low or distorted output from

Input gain(s) for amplifier incorrectly

Readjust input gains of amplifier.

 

 

 

I

 

 

 

 

 

 

G

 

 

 

 

 

 

 

N

the Pass-Thru output of the

set.

 

 

 

 

 

amplifier.

 

 

 

 

 

 

 

 

Source unit output too low.

Check system with known working

 

 

 

 

 

 

 

source and repair or replace original

 

 

 

 

source as needed.

 

 

 

 

 

 

 

 

 

 

 

 

 

XCards are missing or not placed prop-

Check crossover switches and XCard

 

 

 

erly in crossover slots and/or switches

positions and repair or replace as nec-

 

 

 

are not properly selected.

essary.

 

 

 

 

 

 

 

 

 

 

 

 

 

Low battery voltage or large voltage

Check the alternator, battery, fuse or

 

 

 

drops to the amplifier under load.

circuit breaker and power and ground

 

 

 

 

wiring and repair as necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

RCA cable or amplifier connected to

Check connections, substitute

with

 

 

 

Pass-Thru output is defective.

known working amplifier or cables and

 

 

 

 

repair or replace as needed.

 

 

 

 

 

 

 

 

 

 

 

 

If noise persists, see your local Authorized Rockford Fosgate Dealer.

– 43 –

Page 46
Image 46
Rockford Fosgate 250.1 Symptom, Diagnosis, Remedy, Low or distorted output from, the Pass-Thruoutput of the, amplifier