116
Various Other Settings
This instrument contains two sound generators: one for SMF
data playback and one for keyboard performance.
Normally, data received at the MIDI In connector will control
only the sound generator for SMF data playback. However by
changing the MIDI IN Mode setting, you can also control the
keyboard sound generator from MIDI In.
1.

Press the [Utility] button.

2.

Press the Menu [ ] or [ ] button to select

“MIDI.”

3.

Press the [Rec] button.

4.

Press the Menu [ ] or [ ] button to select

“MIDI IN Mode.”

5.

Press the Value [-] or [+] button to change the

setting for MIDI IN Mode.

* When the pedal part button is ON, data received at the MIDI In
connector will control the pedal part of keyboard sound
generator.
When the pedal part button is OFF, data received at the MIDI In
connector will control the GS sound generator.
There are limitations on the types of MIDI messages that can
be received by the keyboard sound generator.
This setting remains stored in memory even while power is
turned off.
To return to the basic screen, press the [Utility] button.
MIDI IN Mode (MIDI IN Mode)
Setting Descriptions
MODE 1
Control the instrument as a GS sound
generator.
MODE 2
Channels 5 through 10 and Channels 12, 14,
15 are transmitted to the GS sound generator,
and all other channels are transmitted to the
keyboard sound generator.
Ch MODE 1 MODE 2
1
GS Solo
2
GS Pedal/GS *
3
GS Lower
4
GS Upper
5–10
GS GS
11
GS Drums/SFX
12
GS GS
13
GS Nothing
14–15
GS GS
16
GS Control