127
Troubleshooting
Troubleshooting
Appendices
Pitch is off
Transpose is in effect.
Simultaneously press the Transpose [-]
and [+] buttons to cancel the
transposition (the Transpose [-] and [+]
buttons’ indicators will go out).
p. 67
The tuning is incorrect. Adjust the standard pitch.
p. 114
While set for an octave shift, you are
playing keys beyond the
recommended range. This does not
indicate a malfunction.
Adjust the Octave Shift setting.
p. 37
Performance data cannot be
played back
While the Utility menu appears in the
display (with the exception of Channel
Mute and Track Mute), playback is not
allowed.
If you wish to playback performance
data, press the [Utility] button once
again to exit the Utility menu
- - -
Recording is not possible
If you wish to erase a previously-
recorded track and then re-record,
press the track button for the desired
track to make that button blink before
you begin recording.
Press the track button for the desired
track to make that button indicator
blink before you begin recording.
p. 94
While the Utility menu appears in the
display, recording is not allowed.
If you wish to record performance
data, press the [Utility] button once
again to exit the Utility menu.
- - -
The recorded performance has
disappeared
Any performance that has been
recorded is deleted when the power to
the ATELIER is turned off.
A performance cannot be restored
once it’s been deleted, so be sure to
save it on a floppy disk before you turn
off the power.
p. 96
The bass note of the Automatic
Accompaniment does not sound
When a voice is selected for the Pedal
Bass part, the bass of the Automatic
Accompaniment will not sound.
This is not a malfunction.
- - -
When you started a Rhythm with
an Intro, the
Rhythm did not sound.
Some Rhythms do not have rhythm
sounds in the intro. This is not a malfunction.
- - -
Sound is distorted / cracked
The Part Balance volume of each part
is too high.
Press the Part Balance button to lower
the volume.
p. 36
The Reverb volume has been raised
when the volume of each Part Balance
button is already raised.
Either lower the Reverb volume, or
adjust the Part Balance of each part.
p. 36
p. 77
The [Master Volume] slider has been
used to raise the overall volume
excessively.
Use the [Master Volume] slider to lower
the overall volume.
p. 18
Some keys (of certain keyboard
parts) sound strange
You are playing notes outside the
recommended range of the voice. This is not a malfunction.
- - -
The Rhythm does not change
when you press the Registration
buttons
The settings at which Registrations are
recalled (Registration Arranger
Update) has been set to “DELAYED.”
Set the timing at which the arranger
settings are called up (Registration
Arranger Update) to “INSTANT.”
p. 57
p. 109
Bass is heard even though you are
not playing the Bass Pedalboard
The Pedal [To Lower] button or the
”Bass Split” function is on.
When the Pedal [To Lower] button is
on, the Bass will be sounded by the
Lower keyboard.
In the Pedal part, press the Pedal [To
Lower] button or ”Bass Split” function is
off.
p. 86
p. 88
When playing the same sound in
the Upper keyboard and Lower
keyboard, the volume is different
On one of the keyboards, “Initial
Touch” is turned ON.
Set the initial touch settings of the
Upper keyboard and the Lower
keyboard to both On, or both Off.
p. 106
Problem Check Solution Page
AT-100-300_e.book 127ページ 2008年5月7日 水曜日 午後3時33分