43
MODE STATUS (Individual area)Address(H) Size(H) Data(H) Parameter Description
——————————————————————————————
03 00 00 01 00-03 Mode Status *1 0: Program Mode
1: Control Mode
2: Note Mode
3: Exclusive Mode
03 01 00 01 00-03 Mode Status *2 0: Program Mode
1: Control Mode
2: Note Mode
3: Exclusive Mode
*1 Outputs on power-up or when Mode change is made.
Also outputs upon receiving Data Request RQ1.
Data Set DT1 is ignored.
*2 Outputs when Data Request RQ1 is received.
Mode is changed when Data Set DT1 is received.
BANK NUMBER (Individual area)Address(H) Size(H) Data(H) Parameter Description
——————————————————————————————
04 00 00 01 00-63 Bank Number *1 0-99
Outputs when Data Request RQ1 is received.
Bank Number is changed when Data Set DT1 is received.
The value exceeding the Bank Limit automatically falls to the limit value.
*1 This is not a Bank Select Number.
EDIT PARAMETERS (Individual area)Address(H) Size(H) Data Parameter Description
——————————————————————————————
05 00 00 01 00000abcBBank Status *1
05 01 00 01 00-63H Bank Limit 0-99
05 02 00 01 rrH Pedal 1 Assign Message *2
05 03 00 01 rrH Pedal 2 Assign Message *2
: : : :
05 0B 00 01 rrH Pedal 10 Assign Message *2
05 0C 00 01 rrH Pedal UP Assign Message *2
05 0D 00 01 rrH Pedal DOWN Assign Message *2
05 0E 00 01 rrH Pedal CTL Assign Message *2
05 0F 00 01 ccH EXP Pedal Assign Message *3
05 10 00 01 rrH Foot SW/EXP 1 Assign Message *2
: : : :
05 15 00 01 rrH Foot SW/EXP 6 Assign Message *2
05 16 00 01 00abcdefB Latch Status Upper *4
05 17 00 01 0ghijklmB Latch Status Lower *4
05 18 00 01 00-03H Mode Jack Loop *5
05 19 00 01 00-08H Note Range C0-C8
05 1A 00 01 00-08H Octave shift High C0-C8
05 1B 00 01 00-08H Octave shift Low C0-C8
05 1C 00 01 01-7FH Note On Velocity 1-127
05 1D 00 01 00/01H Pedal CTL Latch Status *6 OFF/ON
Outputs when Data Request RQ1 is received.
Value of each edit parameter changes when Data Set DT1 is received.
*1 Each bit has the following meaning.
Each bit represents OFF when it is set at “0” and ON when set at “1”.
0000abcB a: Number pedal is used to select Bank.
b: Outputs Program Change information upon Bank
change. c: Outputs Bank Select information.
*2 rr = 01-1F, 21-5F, 60-6B
*3 cc = 01-1F, 21-5F
rr and cc data represent output messages to be assigned to pedal.
01-1F, 21-5F: Controller Number (1-31, 33-95)
60, 61, 62: Realtime Message Start, Stop, Continue
63, 64, 65: MMC(MIDI Machine Control) Command
Stop, Play, Deferred Play
66, 67, 68: MMC Command Fast Foward, Rewind,
Record Strobe
69, 6A, 6B: MMC Command Record Exit, Record Pause,
Pause
* Only Controller Number can be assigned to each Expression pedal.
*4 Each bit reflects latch/momentary setting of each pedal:
0 = momentary; 1 = latch
Latch Status Upper Latch Status Lower
00abcdefB a: Pedal 6 0ghijklmB g: Pedal 1
b: Pedal 7 h: Pedal 2
: :
e: Pedal 10 k: Pedal 5
f: Pedal UP l: Pedal DOWN
m:Pedal CTL
*5 Shows the modes selected by foot switch inserted into the MODE
socket.
Each data sets as shown below:
0: PROGRAM Mode -> CONTROL Mode -> PROGRAM Mode -> ...
1: PROGRAM Mode -> CONTROL Mode -> NOTE Mode ->
PROGRAM Mode -> ...
2: PROGRAM Mode -> CONTROL Mode -> EXCLUSIVE Mode ->
PROGRAM Mode -> ...
3: PROGRAM Mode -> CONTROL Mode -> NOTE Mode ->
EXCLUSIVE Mode -> PROGRAM Mode -> ...
*6 Parameter which changes Pedal CTL Latch Status only. Latch Status
can also be changed by *4 Latch Status.
When both parameters are received, the status of the latter has
priority.
*7 When the massage assigned to the pedal contains information other
than
Controller Number, Latch cannot be turned on.
*8 When transmitting EDIT parameter messages in sequence, the interval
between messages must be 20 msec or longer.
FLIP-FLOP STATUS (Individual area)Address(H) Size(H) Data(H) Parameter Description
——————————————————————————————
06 00 00 01 00/7F Pedal 1 flip-flop OFF/ON
06 01 00 01 00/7F Pedal 2 flip-flop OFF/ON
: : : : :
06 09 00 01 00/7F Pedal 10 flip-flop OFF/ON
06 0A 00 01 00/7F Pedal UP flip-flop OFF/ON
06 0B 00 01 00/7F
Pedal DOWN flip-flop
OFF/ON
06 0C 00 01 00/7F Pedal CTL flip-flop OFF/ON
Outputs when Data Request RQ1 is received.
Flip-flop of each pedal changes when Data Set DT1 is received.
Indicator lights if pedal flip-flop is ON while in the CONTROL CHANGE
Mode.
*1 Ignored if the pedal is set at momentary.
NOTE RANGE STATUS (Individual area)Address(H) Size(H) Data(H) Parameter Description
——————————————————————————————
07 00 00 01 00-08 Current Note Range C0-C8
Outputs when Data Request RQ1 is received.
Current note range is changed upon receiving Data Set DT1.
*1 This is not an Edit parameter.