Using the RMP-5 with Additional Pads
While simultaneously holding down the [METRONOME] and [COACH] buttons, turn on the power.
Afterwards, press the [COACH] button to select the parameter, then press the [+] or [-] button to set the value.
* Press the [METRONOME] button to have selections come up in the reverse order.
Sensitivity
This adjustment determines the pad’s response. Higher values means
higher sensitivity, and the pad will produce a loud sound even when
played softly.
* When you strike the pad, your playing velocity is shown in the display.
Set the value so that the needle appears at the far right when you strike
the pad with maximum velocity.
fig.05-17_80
Threshold
This setting allows the trigger signal to be received only if the pad is
played harder than a specified dynamic. This can be used to prevent
the pad from sounding due to extraneous vibrations from another pad.
In the following example, B will sound but A and C will not sound.
fig.05-10_80
When set to a higher value, no sound is produced when the pad is
struck lightly.
Gradually raise the Threshold value while striking the pad. Check
this and adjust accordingly. Repeat this process until you get the
perfect setting for your playing style.
Velocity Curve
This determines volume changes corresponding to your playing
velocity.
(Linear)
This is the normal setting and produces the most natural correspondence
between playing dynamics and changes in volume.
fig.05-11_80
, (Exponential 1, Exponential 2)
Compared to Linear, a wider volume change will occur for stronger
hits.
fig.05-12_80
, (Log 1, Log 2)
Compared to Linear, wider volume change will occur for softer hits.
fig.05-13_80
Parameter List Parameter Value
Input Mode
(displayed when turning on the power)
Head x 2
Head&Rim
p. 20
Trigger Type PD-8
PD-9, PD-7, PD-6
PD-85
,
PD-80R
,
PD-80
PD-105, PD-100
PD-125, PD-120
KD-8
KD-120
,
KD-85
,
KD-80
,
KD-7
CY-8
CY-15R, CY-14C, CY-12R/C,
CY-12H, CY-6
RT-7K
RT-5S
RT-3T
—
p. 21
Sensitivity 1–16 p. 23
Threshold 0–15 p. 23
Velocity Curve , , , , , , , p. 23
Scan Time 0–4.0 ms (adjustable in increments of 0.1 ms) p. 24
Retrigger Cancel 1–16 p. 24
Crosstalk Cancel , 20–80 (adjustable in increments of 5) p. 24
Mask Time 0–64 ms (adjustable in increments of 4 ms) p. 25
Rim Sensitivity* , 1–20, --- p. 25
Rim Gain 0.5–20, --- p. 25
StrongerWeaker
Threshold
CBA
Volume
Striking Force
LINEAR
Volume Volume
Striking Force
EXPONENTIAL 2EXPONENTIAL 1
Volume Volume
Striking Force
LOG2LOG1