140
Chapter 8 Parameter Guide MASTER

The controllers (sources) controlling targets when an FC-300 is
connected are shown below.
*1 The types of parameters that can be set are the same as those
described in

“EXP PEDAL (Expression Pedal)”

(p. 139).
*2 The types of parameters that can be set are the same as those
described in

“CTL3, CTL4 (Control3, Control4)”

(p. 139).
*3 When an expression pedal is connected, the types of parameters
that can be set are the same as those described in

“EXP PEDAL
(Expression Pedal)”

(p. 139); when a footswitch is connected,
the types of parameters that can be set are the same as those
described in

“CTL3, CTL4 (Control3, Control4)”

(p. 139).
You can freely assign functions to the VB-99’s and FC-300’s
controllers.

FC-300 CONTROL

Source Explanation

FC-300 EXP1 *1 FC-300 expression pedal1
FC-300 EXPSW1 *2 FC-300 expression pedal switch1
FC-300 EXP2 *1 FC-300 expression pedal2
FC-300 EXPSW2 *2 FC-300 expression pedal switch2
FC-300 CTL1 *2 FC-300 control pedal1
FC-300 CTL2 *2 FC-300 control pedal2
FC-300 E3/C3 *3 FC-300 external expression pedal3/external
footswitch3
FC-300 CTL4 *2 FC-300 external footswitch4
FC-300 E4/C5 *3 FC-300 external expression pedal4/external
footswitch5
FC-300 CTL6 *2 FC-300 external footswitch6
FC-300 E5/C7 *3 FC-300 external expression pedal5/external
footswitch7
FC-300 CTL8 *2 FC-300 external footswitch8

ASSIGN 1–16

Parameter/
Range Explanation

SOURCE

This selects the controller to which the function is assigned.
GK VOL GK-3B GK volume knob
GK S1 GK-3B DOWN/S1 switch
GK S2 GK-3B UP/S2 switch
CTL1 Control button1
CTL2 Control button2
EXP PEDAL Expression pedal connected to the EXP
PEDAL jack
D BEAM V D BEAM vertical movements
D BEAM H D BEAM horizontal movements
RIBBON ACT RIBBON CONTROLLER touch
RIBBON POS RIBBON CONTROLLER position
CTL3 Footswitch connected to the CTL3,4 jack
(jack tip)
CTL4 Footswitch connected to the CTL3,4 jack
(jack ring)
FC-300 EXP1 FC-300 expression pedal1
FC-300 EXPSW1 FC-300 expression pedal switch1
FC-300 EXP2 FC-300 expression pedal2
FC-300 EXPSW2 FC-300 expression pedal switch2
FC-300 CTL1 FC-300 control pedal1
FC-300 CTL2 FC-300 control pedal2
FC-300 E3/C3 FC-300 external expression pedal3/external
footswitch3
FC-300 CTL4 FC-300 external footswitch4
FC-300 E4/C5 FC-300 external expression pedal4/external
footswitch5
FC-300 CTL6 FC-300 external footswitch6
FC-300 E5/C7 FC-300 external expression pedal5/external
footswitch7
FC-300 CTL8 FC-300 external footswitch8
INTRNL PEDAL Internal pedal
WAVE PEDAL Wave pedal
INPUT LEVEL Input level
CC Control change

SW

OFF, ON This setting switches the VB-99’s and FC-
300’s controllers on and off.

TARGET PARAMETER

This selects the parameter to be changed.

MIN (Minimum)

This sets the minimum value for the range in which the parameter
can change.
The value differs depending on the parameter assigned for TARGET
PARAMETER.
VB-99_e.book 140 ページ 2008年8月18日 月曜日 午後1時10分