Rosewill RU102 user manual Specification, Operation & Installation, Troubleshooting, RU-101/102

Models: RU102 RU101

1 2
Download 2 pages 45.33 Kb
Page 1
Image 1
Power Protection UPS RU101/102

Power Protection UPS RU101/102

 

 

User Manual

 

 

 

 

 

 

 

 

 

 

 

Turn of the UPS and reduce the amount

 

 

 

The UPS is

The “Battery Backup &

 

 

 

making a

Surge Protection”

of equipment connected to these

 

 

 

continuous sound

outlets are overload.

outlets.

 

 

 

and the “Overload”

 

 

 

 

RU-101/102

indicator is light.

 

Removed all connected equipments

 

 

The UPS does not

Due to age the battery

Rosewill Uninterruptible Power System (UPS) protects your computer hardware from physical

provide expected

does not hold a full

from the UPS and charge the battery at

runtime.

charge

least 8 hours.

damage and will provide emergency battery backup power to prevent data loss in the event of

 

 

Return for service or you can replace

 

 

the battery by ordering one new battery

power problems.

 

 

Connected

The “Battery Backup &

Refer to the Indicator Table “ UPS is

The main features include

equipments lose

Surge Protection”

making a continuous sound and the

‹

Advanced equipment & data protection from blackouts, brownouts, sags, AC line noise and

power while

outlets are overload.

Overload indicator is light”

connected to the

The UPS has

The UPS will turn off when the battery

 

surges.

 

Power the UPS.

exhausted its available

has been depleted during the failure of

 

Full analytical high performance micro-processor control with true RMS synchronous

‹

 

run time.

utility power. Allow UPS to re-charge

 

calculation.

 

 

before continuing using of the UPS.

 

 

Connected equipment is Ensure the equipment that you want to

‹

Intelligent battery management for battery status, battery power saving & battery

 

 

connected to the wrong

stay powered during a failure of utility

 

replacement control.

 

 

 

outlet.

power is plugged into the “Battery

‹

DC direct start-up capability, complete diagnostic indication and control.

 

 

Backup & Surge Protection” outlets.

 

The UPS may be faulty. Please Call your agency for further

‹

Built-in USB communication port for RU102.

 

 

 

troubleshooting.

 

 

 

 

 

‹Phone jack for phone and fax lines for RU102.

Specification

Model

RU-101

 

RU-102

Capacity

600VA/300W

 

1000VA/500W

Input Voltage Range

120V +15%/- 20%

 

 

 

Output Voltage Range

 

120V +/-12%

 

 

 

Frequency

 

50 / 60 Hz auto sensing

Outlets

6 Outlets (3 Battery Backup & Surge)

Lighting / Surge Protection

 

480 Joules

Transfer Time to Battery/AC

 

4 ms (typical)

Battery Type

Sealed and leak proof maintenance free lead-acid battery

Battery Specification

12V/5AH×1

 

12V/9AH x 1

Phone / Fax/ Network

W/O

 

RJ11/RJ45

Protection

 

 

 

 

Short Circuit Protection

 

Circuit breaker

 

 

 

 

Communication Port

W/O

 

USB

 

 

 

Operation Temperature

+32~ 104(0~ 40)

 

 

Operation Relative Humidity

0 to 95% non-condensing

 

 

Storage Temperature

+5~ 113(-15~ 45)

 

 

 

 

Net Weight

7.8 lbs

 

9.12 lbs

 

 

 

 

Dimensions (WxDxH) inch

6.1×4.3×8.3

 

7.1x6x9.5

 

 

 

 

Operation & Installation

Rosewill UPS can protect your equipment from all power problems such as surge, spikes, blackouts, brownouts and line noise. When AC power is present and the ON/OFF switch is turned on, Rosewill UPS continues to charge the battery and provide the power to the equipment directly from the AC line. The battery can provide stable power to complete your work, save your data and safely shut down your system when the utility power has failed.

Rosewill UPS is simple to operate and install. Following are the installation steps to connect he equipment to the UPS.

1.Connect Rosewill UPS to grounded AC power Outlets.

2.Charge the battery at least 8 hours for a full charge before use.

3.Plug your computer and monitor into the “Battery Backup & Surge Protection” outlets. (These outlets will provide emergency battery backup power during power problems as well as surge protection from surge and spike.)

CAUTION: Do NOT plug LASER PRINTERS into any of the “Battery Backup” outlets.

CAUTION: Do NOT plug ACCESSORY SURGE STRIP into any of the “Battery Back & Surge Protection” outlets.

4.Plug your peripheral equipment (printer, scanner, fax, speaker, etc.) into the “Surge Protection” outlets. (These outlets will NOT provide battery backup power during a utility power failure).

5.Switch on the Rosewill offline UPS product while the connected equipment is off,.

6.Turn on your connected equipment when the “AC mode” LED light is illuminated.

Troubleshooting

Symptom

Possible Cause

Action to Take

The UPS will not

UPS is not turn on

Switch on the On/Off switch. If the

turn on.

 

power is not present, please make sure

 

 

your circuit breaker on the building is not

 

 

accidentally turned off.

 

Circuit Breaker has

Reduce the amount of equipment

 

tripped.

plugged into the “Battery Backup &

 

 

Surge Protection” outlets of the UPS.

 

 

Next, rest the circuit breaker by pushing

 

 

it back in.

Indicators

600VA/300W

1000VA/500W

1.On/Off Switch

This On/Off switch controls power to your equipment and performs a self-test to detect inverter, line, battery status & LEDs.

NOTE: Turn on the UPS.

Press and hold the switch for more than two seconds and release the switch after the beep. The UPS will start and provide the stable power to your equipments.

NOTE: Turn off the UPS.

Press and hold the switch for more than two seconds and release the switch. The UPS will shut down completely.

NOTE: Perform Self-test.

The UPS will perform self-test for about 10 seconds when the UPS is turned on.

2.Line / Battery LED (Green LED)

Indicates the UPS is providing AC power to your equipment. When the LED is blinking the UPS is providing power from the battery.

3.Warning LED (Red)

Page 1