Rotel RMB-1076 Troubleshooting Specifications, Front Panel Power Indicator Is, Not Lit, No Sound

Models: RMB-1076

1 46
Download 46 pages 52.14 Kb
Page 8
Image 8

RMB-1076Six Channel Power Amplifier

8

Troubleshooting

Specifications

 

Most difficulties in audio systems are the result

Power Configurations

6 x 100 watts

of poor or wrong connections, or improper

Watts/Channel

100 watts

control settings. If you encounter problems,

All channels driven, with 20KHz filter unbridged, 8ohm, 20 to 20kHz, <0.02%THD

isolate the area of the difficulty, check the

Total Harmonic Distortion

< 0.02%

control settings, determine the cause of the

At rated power, 20-20,000Hz

 

fault and make the necessary changes. If you

Intermodulation Distortion

< 0.03%

are unable to get sound from the RMB-1076,

At rated power, 60 Hz : 7 kHz, 4:1

 

refer to the suggestions for the following

Power Output 4 ohms, 1.0% THD

180 watts

conditions:

Frequency Response ±3 dB

10Hz–40kHz

Front Panel Power Indicator Is

Damping Factor 8 ohms

200

Signal to Noise Ratio IHF A network

105 dB

Not Lit

Amp Gain

27.2dB

No main power to the RMB-1076. Check AC

Input Sensitivity / Impedance

1.25V/8.2 kohms

power connections at the amplifier and the

Auto Turn On Threshold Level (if activated)

10 mV input signal

AC outlet. Check the front panel power switch.

Power Requirements

 

Make sure that it is set to the ON position. If

USA:

120 Volts, 60 Hz

using signal sensing auto power-on, make

Europe:

230 Volts, 50 Hz

sure that a signal is present at the inputs. If

Power Consumption

300 Watts

using 12V trigger power-on, make sure that

Output Peak Current

11A

a trigger signal is present at rear panel screw

Idling Power Consumption

70 watts

terminals.

Standby Power Consumption

6 watts

No Sound

Dimensions (W x H x D)

432 x 72 x 382 mm

 

17 1/8 x 9 3/8 x 15 1/8 in

If the amp is getting AC power, but is producing

Front Panel Height (for rack mount)

60mm

no sound, check the PROTECTION INDICATOR

Weight (net)

5.7 kg, 12.5 lb.

on the front panel. If lit, see below. If not, check

 

 

all of your connections and control settings on

All specifications are accurate at the time of printing.

 

associated components. Make sure that your

Rotel reserves the right to make improvements without notice.

 

input connections and speaker connections

 

 

match your selected configuration.

 

 

Protection Indicator Is Lit

The front panel PROTECTION INDICATOR is lit when the RMB-1076 protection circuits have shut off the amplifier. Typically, this occurs only when the ventilation openings are blocked, when there is faulty speaker wiring, or after a period of extreme use. Turn off the system and wait for the amp to cool. Then push the front panel power switch in and out to reset the protection devices. If the problem is not corrected or reoccurs, there is a problem with the system or the amplifier itself.

Page 8
Image 8
Rotel RMB-1076 owner manual Troubleshooting Specifications, Front Panel Power Indicator Is, Not Lit, No Sound