2. Troubleshooting

2.1 Rollers Not Heating

CAUSES

1.The wire connector from the heater is disconnected with MAIN PCB.(except RSL-380)

2.The Wire-Temp Fuse is disconnected.

3.The Main Fuse is defective.(except RSL-380)

4.The Bi-metal is defective.

5.The heater in the roller is defective.

6.Main PCB is defective.

MEASURES

Before troubleshooting, be sure to disassemble the Right cover ,

the Left cover and the Frame Rear. Refer to how to replace each component for the disassembly of them.

1. The wire connector from the heater is

disconnected with MAIN PCB.(except RSL-380)

1)Test if the connector wire is disconnected with Multi-tester.

2)If disconnected, replace it with new one.

WIRE-

HEATER

4

Page 5
Image 5
Royal Sovereign RSL-2701U, RSL-380 service manual Troubleshooting, Rollers Not Heating