Royal Sovereign RSL-380 RSL-2701,RSL-2701U, Sensor Assy position Wire thermal fuse is defective

Models: RSL-2701 RSL-2701U RSL-380

1 42
Download 42 pages 43.77 Kb
Page 9
Image 9

RSL-2701RSL-2701U

1.The Temperature Sensor is not work.

1)Disassemble the Right and the Left cover. (Refer to how to replace Cover.)

2)Disassemble the Bracket-Sensor with Sensor ass'y.

Test if the Sensor ass'y is disconnected with Multi-tester.

SENSOR ASS'Y

BRACKET SENSOR

<Sensor Ass'y position>

<Sensor Ass'y>

2.The wire thermal fuse is defective.

1)Test if the wire thermal fuse is disconnected with Multi-tester.

2)If disconnected, replace it with new one.

3.The heater in the roller is defective.

1)Test if the heater is disconnected with Multi-tester.

2)If disconnected, replace it with new one.

4.Main PCB is defective.

1)Replace Main PCB with new one according to How to replace Main PCB only when all of the above mentioned heater wire, wire thermal fuse, heater and Bi-metal are normal.