Royal Sovereign Wire-Temp Fuse is disconnected, Main Fuse is disconnected.except RSL-380

Models: RSL-2701 RSL-2701U RSL-380

1 42
Download 42 pages 43.77 Kb
Page 6
Image 6

2The Wire-Temp Fuse is disconnected

1)Test if the Wire-Temp Fuse is disconnected with Multi-tester.

2)If disconnected, replace it with new one.

WIRE-TEMP FUSE

3.MAIN FUSE is disconnected.(except RSL-380)

1)Test if the Main Fuse is disconnected with Multi-tester.

2)If disconnected, replace it with new one.

4.The Bi-metal is defective.

1)Disconnect the heater wire from the Bi-metal.

2)Unfasten 2 screws holding the Bi-metal.

3)Replace it with new one.

MAIN

FUSE

BI-METAL

5

Page 6
Image 6
Royal Sovereign Wire-Temp Fuse is disconnected, Main Fuse is disconnected.except RSL-380, Bi-metal is defective