3.3 Fiber Optical Port Specifications

Speed

Standard

100BaseFX

100BaseFX

100BaseFX

100BaseFX

100BaseFX

100BaseFX

 

Mode /

 

 

Tx λ

 

 

Cable

 

 

Tx Pwr

 

 

Rx

 

 

Rx Saturation

 

 

Typical

 

 

Power

 

 

 

 

 

 

Type2

 

 

(dBm peak) 3

 

 

Sensitivity

 

 

 

 

Distance

 

 

Budget

 

 

Connector

 

 

(nm)

 

 

(dBm Peak) 3

 

 

 

 

 

 

(µm)

 

 

(Min / Max)

 

 

(dBm Average) 3

 

 

 

 

(km) 1

 

 

(dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MM / ST

1310

 

50/125

 

-15.7

 

-33.5

 

-11

 

2

 

17

 

 

MM / SC

1310

 

50/125

 

-16/-11

 

-33

 

-11

 

2

 

17

 

 

MM / LC

1310

 

50/125

 

-19 / -14

 

-32

 

-14

 

2

 

15

 

 

MM / MTRJ

1310

 

50/125

 

-16/-11

 

-33.5

 

-11

 

2

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM / SC

1310

 

9/125

 

-13/5

 

-31

 

-4

 

20

 

20

 

 

SM / LC

1310

 

9/125

 

-15/-8

 

-31

 

-5

 

15

 

16.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and splices. Please consult RuggedCom sales associates when determining maximum segment distances.

2.To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.

3.4Networking Standards Supported

Parameter

10FL

100FX

Notes

 

Module

Module

 

IEEE 802.3

￿

 

10BaseT

IEEE 802.3u

 

￿

100BaseTX / 100BaseFX

IEEE 802.3x

￿

￿

FDX, Flow Control

12

2006 RuggedCom Inc. All rights reserved

Rev101

Page 12
Image 12
RuggedCom RMC40 manual Fiber Optical Port Specifications, Networking Standards Supported, Parameter 10FL 100FX Module