RuggedCom RMC40 Fiber Optical Port Specifications, 3.4Networking Standards Supported, Notes, 10FL

Models: RMC40

1 16
Download 16 pages 54.9 Kb
Page 12
Image 12
3.3 Fiber Optical Port Specifications

3.3 Fiber Optical Port Specifications

Speed

Standard

100BaseFX

100BaseFX

100BaseFX

100BaseFX

100BaseFX

100BaseFX

Mode /

Connector

MM/ ST

MM / SC

MM / LC

MM / MTRJ

SM / SC

SM / LC

Tx λ

(nm)

1310

1310

1310

1310

1310

1310

Cable Type2

(µm)

50/125

50/125

50/125

50/125

9/125

9/125

Tx Pwr

(dBm peak) 3

(Min / Max)

-15.7

-16/-11

-19 / -14

-16/-11

-13/5

-15/-8

Rx

Sensitivity

(dBm Average) 3

-33.5

-33

-32

-33.5

-31

-31

 

Rx Saturation

 

 

Typical

 

 

Power

 

 

 

 

Distance

 

 

Budget

 

 

(dBm Peak) 3

 

 

 

 

(km) 1

 

 

(dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-11

 

2

 

17

 

-11

 

2

 

17

 

-14

 

2

 

15

 

-11

 

2

 

17

 

-4

 

 

 

 

 

 

20

 

20

 

 

 

 

 

 

 

-5

 

15

 

16.5

 

 

 

 

 

 

 

 

 

 

Notes:

1.Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and splices. Please consult RuggedCom sales associates when determining maximum segment distances.

2.To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.

3.4Networking Standards Supported

Parameter

10FL

100FX

Notes

 

Module

Module

 

IEEE 802.3

￿

 

10BaseT

IEEE 802.3u

 

￿

100BaseTX / 100BaseFX

IEEE 802.3x

￿

￿

FDX, Flow Control