ADJUSTMENTS

FENCE

4

5

30

15

45

 

 

0

31.62

30

22.5

15

BLADE

MITER TABLE

FRAMING SQUARE

VIEW OF BLADE NOT SQUARE WITH

FENCE, ADJUSTMENTS ARE REQUIRED

Fig. 25

Using the 6 mm hex key provided, loosen the socket head screws that secure the mounting bracket to the miter table. See Figure 26.

R O T A T I O N

SQUARING THE BLADE TO THE

MITER TABLE

See Figures 27 – 31.

Remove battery pack from saw.

WARNING:

Failure to remove battery pack from your saw could result in accidental starting causing possible serious personal injury.

Pull the saw arm all the way down and engage the lock pin to hold the saw arm in transport position.

Lift up the miter table clamp.

Rotate the miter table until the pointer is posi- tioned at 0°.

Push the miter table clamp back down.

Loosen bevel lock knob and set saw arm at 0° bevel (blade set 90° to miter table). Tighten bevel lock knob.

Place a combination square against the miter table and the flat part of saw blade.

Note: Make sure that the square contacts the flat part of the saw blade, not the blade teeth.

Rotate the blade by hand and check the blade-to- table alignment at several points.

The edge of the square and the saw blade should be parallel as shown in figure 27.

6 mm SOCKET

HEAD SCREW(S)

FENCE

6 mm

HEX KEY MOUNTING

BRACKET

15

.5 22

31.62

0

3

45

 

MITER TABLE

Fig. 26

4

5

30

15

45

 

 

0

31.62

30

22.5

15

BLADE

Rotate the mounting bracket left or right until the saw blade is parallel with the square.

Retighten the screws securely and recheck the blade-to-fence alignment.

MITER TABLE

COMBINATION

SQUARE

VIEW OF BLADE SQUARE

 

WITH MITER TABLE

Fig. 27

20

Page 20
Image 20
Ryobi MS180 warranty Squaring the Blade to Miter Table, See Figures 27, Fence HEX KEY Mounting Bracket