Step 3

While the solution is flowing into the freezing cylinder, take particular care to brush-clean the mix level sensing probe on the bottom of the hopper, the mix hopper, the mix inlet hole, and the feed tubes.

Step 4

Place the power switch in the ON position.

Step 5

Touch the WASH symbol / and allow the sanitizing solution in the freezing cylinder to agitate for five minutes.

Step 6

With a pail beneath the door spout(s), open close the draw valve six times. Then open the draw valve and draw off the sanitizing solution.

Step 7

Touch the WASH symbol / and close the draw valve.

Figure 38

Note: Be sure your hands are clean and sanitized before going on in these instructions.

Step 8

Lubricate the o-rings on the inner and outer feed tubes. DO NOT lubricate the o-ring on the air orifice. Place the inner feed tube inside the outer feed tube.

Figure 39

Step 9

Install the air orifice into the hole in the top of the inner feed tube.

Figure 40

Note: Make sure the hole in the air orifice is clean and is not clogged. If the hole in the air orifice should become clogged, use soap and hot water to clear the hole. Do not enlarge the hole in the air orifice.