Step 8
Slide the pivot pin through the draw handles as the handles are inserted into the draw valves.
Figure 30
Note: This freezer features adjustable draw handles to provide portion control, giving a better consistent quality to your product and controlling costs. The draw handles should be adjusted to provide a flow rate of 5 to
To INCREASE the flow rate, turn the adjustment screw CLOCKWISE. To DECREASE the flow rate, turn the adjustment screw COUNTER-
CLOCKWISE.
Step 9
Snap the design caps over the bottom of the door spouts.
Step 10
Slide the long drip pan into the hole in the front panel. Slide the other two drip pans into the holes in the side panels. (See Figure 31.)
Figure 31
140121
Step 11
Install the front drip tray and splash shield under the door spouts. (See Figure 32.)
Figure 32
Feed Tube Assembly
Step 1
Slide the three
Figure 33
Operating Procedures | 36 | Models C709 & C717 |
|
|
|