Taylor manual Models C709 & C717, Important To the Operator

Models: C717 C709

1 69
Download 69 pages 16.18 Kb
Page 33
Image 33

The third screen shows the right side (R) of the freezer.

The top line of these screens shows the hopper (H) and barrel (B) temperatures recorded at the end of the Heat Treat Cycle and indicates the side (L or R) of the freezer.

The remaining lines indicate the following:

HEAT = Total time for the hopper (h) and barrel (b) to reach 150.9°F (66.1°C).

OVER = Total time the hopper (h) and barrel (b) temperature was above 150°F (65.6°C).

COOL = Total time the hopper (h) and barrel (b) temperature was above 41°F (5°C) during the COOL phase.

PEAK = Highest temperature reading for the hopper

(h) and barrel (b) during the Heat Treatment Cycle.

H: 40.9

 

B:26.3

L

HEAT

OVER

 

COOL

PEAK

1:12

0:49

h

1:19

161.0

0:46

1:11

b

0:15

169.7

 

 

 

 

 

 

 

 

H: 38.0

 

B:23.7

R

HEAT

OVER

 

COOL

PEAK

1:09

0:52

h

1:11

161.2

0:66

1:00

b

0:11

169.9

 

 

 

 

 

The HEAT time indicates the amount of time taken in each zone to reach 150.9°F (66.1°C). Each zone must remain above 150°F (65.6°C) for a minimum of 35 minutes.

Touch the UP arrow symbol to advance to the next page or the DOWN arrow symbol to view the previous page. A Heat Cycle Failure message will display on the first screen if a failure occurred.

Listed below are variable failure code messages which could appear on line 2.

HT

HEAT TIME FAILURE

 

Mix temperature did not rise above 151_F

 

(66.1_C) in less than 90 minutes.

CL

COOL MODE FAILURE

 

Mix temperature in the hopper and freezing

 

cylinder did not fall below 41_F (5_C) in less

 

than 90 minutes for UVC3 units or 120

 

minutes for UVC4 units.

TTTOTAL TIME FAILURE

The heat treatment cycle must be completed in no more than 4 hours.

ML

MIX LOW FAILURE

 

The Heat Phase or Cool Phase time was

 

exceeded and a mix low condition was

 

present.

MO

MIX OUT FAILURE

 

A mix out condition was detected at the start

 

or during the heat cycle.

BO

BEATER OLVD IN HC

 

A beater overload occurred during the heat

 

cycle.

HO

HPCO IN HEAT CYCLE

 

A high pressure cut-out condition occurred

 

during the heat cycle.

PF

POWER FAILURE IN HC

 

A power failure caused the Heat Phase,

 

Cool Phase, or Total Cycle Time to exceed

 

the maximum allowed time. If a power failure

 

occurs, but the heat treatment cycle does

 

not fail, an asterisk(*) will appear on the third

 

line of the display.

OP

OPERATOR INTERRUPT

 

Indicates the heat cycle was aborted in the

 

OPERATOR INTERRUPT option in the

 

Service Menu.

PS

POWER SWITCH OFF

 

The power switch was placed into the OFF

 

position during the heat cycle.

TH

THERMISTOR FAILURE

 

A thermistor probe has failed.

PD

PRODUCT DOOR OFF

 

A product door is not in place or is loose.

140303

Models C709 & C717

29

Important: To the Operator

 

 

 

Page 33
Image 33
Taylor manual Models C709 & C717, Important To the Operator