BLK
BLK
| BLK |
|
| CompanyTaylor | C709Model | 05701058- | 06/14 |
BLU |
|
|
| ||||
ORN | M | PUR |
| ||||
MIX |
|
|
| ||||
PUMP | RED |
|
| ||||
MOTOR |
|
| |||||
|
| YEL | |||||
START | 3 | 2 |
|
|
|
|
|
RELAY |
| 4 |
|
|
|
|
|
WHT |
|
|
|
|
|
|
|
BRN |
|
|
|
| WHT |
|
|
|
|
| GRN/YEL |
| |
| BLK | BLK |
|
| WHT |
|
|
|
| L1 | LINE | L2 |
|
|
| EMI FILTER |
| |||
|
|
| L1 | LOAD | L2 |
|
|
|
|
| 240V |
|
|
|
| BLK |
| NOT |
|
|
|
| CONNECTED WHT |
| |||
|
| BLK |
| WHT RED | ORN |
|
| INTERFACE BOARD |
|
|
|
| |
| POWER TRANSFORMER |
|
|
| ||
|
|
| BLU | 16V | RED |
|
|
|
|
|
| ||
|
|
|
|
| BRN/WHT | SHIELD CUT |
|
|
|
|
|
| NO CONNECTION |
|
|
|
|
|
| THIS END |
|
|
|
| BLU RED |
|
|
|
|
|
|
|
| RED |
|
|
|
|
|
| BLU |
|
|
|
|
|
| GRN/YEL |
| GRN/YEL |
|
|
|
|
|
| HOPPER |
|
|
|
|
|
| GROUND |
|
|
|
|
|
| ON | RED/WHT |
|
| BRN/WHT |
|
| OFF | WHT/RED |
|
|
| |
BRN | ON | BRN/WHT |
|
|
| BRN/WHT |
| BLK |
|
|
|
|
|
POWEROFF
SWITCH
DPDT
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BRN/WHT |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BRN |
|
|
CLR (+5V) | J1 |
| USER | - 8 LEDS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
BLK (GRD) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| - LCD SCREEN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| J3 | INTERFACE | - 9 KEYS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| BOARD | - BEEPER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
CABLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| RIBBON CABLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
J16 | J4 | J2 |
| J7 | J9 | GRN WHT RED BLK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
1 5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 6 |
|
|
| J13 | 5 6 2 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
4 3 8 7 |
|
|
|
|
| 4 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
J12 | J15 |
|
|
| J8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
UNIVERSAL CONTROL PCB A. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
J17 |
|
|
|
|
| J1 | GRD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BLK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
CLR | J10 |
|
| J11 |
| 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| +5v |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RIBBON CABLE |
|
|
|
|
|
|
|
| RIBBON | CABLE |
|
|
|
|
|
|
| |
|
|
| RED |
|
|
|
|
|
| RED |
|
|
|
|
|
|
|
|
|
| |||
|
|
| BLU |
|
|
|
|
|
| BLU |
|
|
|
|
|
|
|
|
|
|
|
| |
|
| GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SV CABLE |
|
|
|
|
|
|
| SV CABLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| RED | B A |
|
|
|
|
|
|
|
|
|
|
|
|
|
| RED/WHT |
|
|
|
|
|
| BLU |
|
| J2 |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| RED/BLK |
|
| 4 3 2 1 |
|
|
| J3 |
| BLK |
|
|
|
|
| |
NC |
|
|
|
|
|
| BLK |
|
|
|
| 8 7 6 5 J14 |
|
|
| GND |
|
|
|
|
|
| |
|
|
| GRA/BLK |
|
|
|
|
|
|
|
|
|
| +5V |
| CLR |
|
|
|
|
| ||
COM |
|
|
|
|
| GRN/YEL |
|
|
|
|
|
|
|
|
|
| BEATER MOTOR WIRE MUST GO | ||||||
|
|
|
| PRP/WHT |
|
|
|
| 9 |
|
|
|
|
|
|
| THRU SENSOR CORE TWICE |
| |||||
NO |
|
|
|
|
|
|
|
|
|
|
| 10 |
|
|
|
| 8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3456782 1 J10 J11 J12 |
| J13 |
|
| 213 4 5 6 7 |
|
|
|
|
|
| |
|
| MIX |
| PRP/WHT |
| PROBE | YEL BLK | YEL | BLK | (OPTIONAL) |
|
|
|
|
|
|
|
|
| ||||
DRAW |
| OUT |
|
|
| INTFC PCB A. J5 |
|
|
|
|
|
| |||||||||||
SWITCH |
| PROBE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TAN |
|
|
|
| |
|
|
|
|
|
| MIX |
|
|
|
|
|
|
|
|
|
|
|
| BLK |
|
|
|
|
|
|
|
|
|
|
|
|
| SELF SERVICE |
|
|
|
|
|
|
| BLK |
|
|
|
| ||
|
|
|
|
|
| LOW |
|
|
|
| ENABLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| WITH SOFT SERVE |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ENABLE |
|
| PERSONALITY PCB A. |
|
|
|
|
|
| |||
|
|
|
|
|
|
| 4 |
| 5 | YEL | BLK | J9 |
|
| L2 |
| L1 | WHT |
|
|
|
|
|
|
|
|
|
|
|
| BARREL HOPPER |
| DISABLE | J8 |
| J7 | J6 | BLK |
|
|
|
|
| ||||
|
|
|
|
|
|
|
| 5 | 3 | 1 1 2 3 4 5 6 7 | 1 2 3 4 5 6 7 |
|
| FUSE |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 15A |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BLK |
|
|
|
|
|
|
| BLU |
|
|
|
|
| ONE SIDE OF A | BLK |
| BLK |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| BRN/WHT | TWO WIRE CORD |
|
|
| WHT/ORG |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ORG/WHT |
| BLK | *C708* |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| BLK | BLK |
|
|
| ORN |
|
| OVERLOAD |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BARREL | SWITCH |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| COMPRESSOR |
|
|
|
| SUCTION |
| GRN/YEL |
|
| |||
|
|
|
|
|
|
|
|
|
|
| LIMIT SWITCH |
|
|
|
| SOLENOID |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| HIGH PRESSURE |
|
|
|
| BLK |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ORN | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RED |
|
|
| M PUR |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| BLK | COMPRESSOR |
| MIX |
|
| BEATER | |||
|
|
|
|
|
|
| 96 | 95 | BLK | BLK | BLK |
|
| CONTACTOR | WHT | PUMP |
| YEL | |||||
|
|
|
|
|
|
|
|
|
| COIL |
|
| (SEE FIG 2)RED |
| RELAY | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| WHT |
|
|
| MOTOR |
|
| MOTOR | ||
|
|
|
|
|
|
| BEATER |
|
|
|
|
|
|
|
|
|
|
| START 3 | 2 |
| COIL | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RELAY |
|
| WHT | ||
|
|
|
|
|
|
| MOTOR |
|
|
|
|
|
|
|
|
|
|
|
| 4 |
| ||
|
|
|
|
|
|
| OVERLOAD |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| SWITCH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BRN/WHT |
|
|
| |
|
|
|
|
| EXTERNAL EQUIPOTENTIAL |
|
|
|
|
|
|
| |||
|
|
|
|
| GROUND | GROUND |
|
|
|
|
|
|
|
| |
|
|
|
| L1 L2 L3 | N |
|
|
|
|
|
|
|
|
|
|
TERMINAL BLOCK |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| BLK BLK BLU |
| GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
| WHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GRN/YEL |
|
| ELECTRICAL |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| ENCLOSURE |
|
|
|
|
|
|
|
| |
|
|
| WHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| WHT |
|
|
|
|
|
|
|
| |
|
|
|
|
| WHT |
|
|
|
|
|
|
|
| BRN/WHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| GRA/BLK |
|
|
|
|
|
|
|
|
|
|
| BARREL |
| |
|
|
|
|
|
|
|
|
| 1 |
| 4 | 8 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| HOT GAS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SOLENOID |
|
|
|
|
|
|
| BLU/WHT |
|
|
| 2 |
| 6 3 |
| RELAY |
|
|
|
|
|
|
|
|
|
| 0 |
| 7 |
|
| ||
|
|
|
|
|
| GRN/YEL |
|
|
|
|
|
| BRN/WHT |
| |
|
|
|
|
| BLK |
| GRA |
|
|
|
|
|
|
| |
|
|
|
|
|
| BARREL |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| HOT GAS |
|
|
|
|
|
|
|
| |
GRA |
|
|
|
| SOLENOID |
|
|
|
|
|
| HOPPER |
| ||
|
|
|
|
|
|
|
|
| 1 |
| 4 | 8 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| HOT GAS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SOLENOID |
|
| AGITATOR |
|
| BLU/WHT |
|
|
|
|
|
| RELAY |
| |||
| BLU |
| M RED | BLU/WHT |
| HOPPER |
|
| 0 | 2 |
| 6 3 | 7 |
|
|
|
| MOTOR |
|
| GRN/YEL |
|
|
|
|
|
|
|
|
| |
|
| SEE |
|
|
|
|
|
|
|
|
|
|
|
| |
|
| DETAIL |
| BLK |
|
| YEL |
|
|
|
|
|
|
| |
|
|
|
|
| WHT | HOT GAS | WHT | COM | 240 |
|
|
| BLK |
|
|
|
| WHT |
| SOLENOID |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| BLU |
|
|
| BLU/WHT | BLU/WHT |
| 24 VAC |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| GRN/YEL | BLU/WHT |
|
| BLK/RED |
|
|
|
|
| |
|
|
|
|
| GRN/YEL |
|
|
|
|
|
|
| |||
|
|
|
|
| BLU/WHT |
|
|
| BLU |
| BLUE |
|
|
| |
|
|
|
| WHT |
|
|
|
|
|
|
|
|
|
|
|
|
| BLK | BLK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BLK |
|
|
|
|
|
|
|
|
|
|
|
|
|
| WHT |
|
|
|
|
|
| |
GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| BEATER |
|
| |
|
|
| WHT/ORG |
|
|
|
|
|
|
| INTERLOCK |
|
| ||
|
|
|
|
|
|
|
|
|
| RELAY |
|
| |||
|
|
|
|
|
| BLU/WHT |
|
|
|
|
|
| 5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 9 |
|
|
|
ORN |
|
|
|
|
|
|
|
|
|
|
|
| 8 | TAN | BLUE |
|
|
|
|
|
|
|
|
|
|
|
|
| 4 |
|
|
|
|
|
|
|
|
|
| WHT/ORN |
|
|
| 12 |
|
|
|
| SNUBBER |
|
|
| GRN/YEL |
|
|
|
| BLK |
| 13 | 14 |
|
|
WHT | BLK | BLK |
| WHT | INTERLOCK |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| BEATER |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| MOTOR |
|
| BLK |
|
|
| ||
|
|
|
|
|
|
| N.O. SWITCH |
|
|
|
|
|
|
|
|
|
|
| FIG 2 |
|
|
|
|
|
|
|
| |||
| ALTERNATE MIX PUMP MOTOR WIRING |
|
| JUMPER SETTINGS |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| UVC4 |
| JUMPER |
|
|
|
|
|
|
|
|
|
|
|
|
|
| FUNCTION | INSTALLED |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| BOARD |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| INITIALLY |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| JUMPER INSTALLED- BARREL AND HOPPER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TEMPERATURES ARE CHECKED DURING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AUTO/STANDBY. UNIT IS LOCKED OUT IF |
|
|
| ADDITIONAL DRAW SWITCH |
|
|
|
|
| EITHER BARREL OR HOPPER IS TOO WARM FOR |
|
| |||||||
|
| FOR FLAVORBURST |
|
|
|
|
| A PERIOD OF TIME. LOCKOUT OCCURS WHEN |
|
| ||||||
|
|
|
|
|
| PINS 1 AND 2 | BARREL OR HOPPER IS ABOVE 45 F (7 C) | YES |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| JP1 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| FOR MORE THAN ONE HOUR OR ABOVE 41 F |
|
| |
|
|
|
|
|
|
|
|
|
|
| PANEL |
|
| (5 C) FOR MORE THAN FOUR HOURS. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NO JUMPER |
|
| |
|
|
|
|
|
|
|
|
|
|
| JACK |
|
| AUTO/STANDBY IF BARREL OR HOPPER IS TOO |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| WARM FOR A PERIOD OF TIME. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| PINS 3 AND 4 | RESERVED (DO NOT USE) | NO | . |
|
| NC |
|
|
|
|
|
|
|
| DOMESTIC |
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| HOPPER TEMPERATURE NOT DISPLAYED ON |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| C0M |
|
|
|
|
| SCREEN/HEAT SYMBOL KEYS ONLY ACTIVE |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| WHEN A LOCKOUT CONDITION HAS OCCURRED/ |
|
|
DRAW |
|
|
| JP2 | PINS 1 AND 2 | STANDBY KEYS DISABLED. | NO |
| ||||||||
SWITCH NO |
|
|
|
|
| INTERNATIONAL |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| INSTALLED. HOPPER TEMPERATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DISPLAYED ON SCREEN/MANUAL HEAT CYCLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| START BY SELECTING HEAT SYMBOL/STANDBY |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| KEYS FUNCTIONAL. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| JP3 |
| RESERVED (DO NOT USE) | NO |
|
|
|
|
|
|
|
|
|
|
|
|
| JP4 |
| RESERVED (DO NOT USE) | NO |
|
|
|
|
|
|
|
|
|
|
|
|
| JP5 |
| RESERVED (DO NOT USE) | NO |
|
|
|
|
|
|
|
|
|
|
|
|
| JP6 |
| RESERVED (DO NOT USE) | NO |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| JP7 |
| JUMPER INSTALLED DISABLES RESET. | NO |
|
|
|
|
| SE |
|
|
|
|
|
|
|
| ||||
|
|
|
| RTCK |
| RESERVED (DO NOT USE) | NO |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| DBGEN |
| RESERVED (DO NOT USE) | NO |
|
|
|
|
| M |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| INTERFACE |
| JUMPER |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| BOARD | FUNCTION | INSTALLED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| INITIALLY |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
RED |
|
|
|
|
|
|
|
| BLUE |
|
| W1 |
| RESERVED (DO NOT USE) | NO |
|
|
|
|
| WHT |
|
| W2 |
| JUMPER | NO |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| W3 |
| RESERVED (DO NOT USE) | NO |
|
|
|
|
|
|
|
|
|
|
|
|
| W4 |
| JUMPER | NO |
|
|
|
|
|
|
|
|
|
|
|
|
| W5 |
| RESERVED (DO NOT USE) | NO |
|
|
|
|
|
|
|
|
|
| BLUE | W6 |
| JUMPER | NO |
| ||
BLU/WHT |
|
|
|
|
|
|
|
| W7 |
| JUMPER | NO | Carrier | |||
|
|
|
|
|
|
|
|
| PINS 1 & 2 | JUMPER | YES | |||||
|
|
|
|
|
|
|
|
| TEMPERATURE CHECK. | |||||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| J10 |
| JUMPER INSTALLED |
| |||||
| AGITATOR |
| PINS 7 & 8 | APPLICATION ONLY. LOCKS OUT TOUCH | NO | |||||||||||
|
| PANEL. NEW SWITCH ACTS AS THE ON/OFF | ||||||||||||||
|
|
|
| |||||||||||||
| MOTOR DETAIL |
|
| ABILITY TO ACTIVATE THE TOUCH PANEL. |
|
BLK
BRN
BRN/WHT
|
|
|
|
|
|
|
| WHT |
|
|
|
|
| WHT | ORN |
|
|
|
| WHT |
|
|
|
|
|
|
|
|
| WHT |
|
|
|
|
|
|
|
| WHT/GRA | HOPPER | GRN/YEL |
| BLK |
| WHT |
| |
|
|
|
|
|
|
| LIQUID | GRN/YEL |
|
|
|
|
| ||
|
|
|
|
|
|
|
| SOLENOID |
|
|
| BLK |
|
|
|
|
|
| WHT/BRN |
|
|
|
| LIV | GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| GRA/WHT |
| SELENOID | GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
| BARREL |
|
|
|
| WHT |
| |||
|
|
|
|
|
|
| LIQUID |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| SOLENOID |
|
|
|
|
| WHT |
| |
|
|
|
|
|
|
|
|
| BLK | BLK | SOFT SERVE | GRN/YEL |
| ||
|
|
|
|
|
| BEATER MOTOR | BEATER |
|
|
|
| ||||
|
|
|
|
|
| STARTER |
|
| MOTOR |
|
|
|
| ||
|
|
|
| BLK |
|
|
| L1 | T1 |
| M BLK T2 | L2 | BLK |
| |
|
|
|
| SOFT SERVE |
|
|
|
|
|
|
|
|
| BLK |
|
|
|
|
| COMPRESSOR |
|
|
|
|
|
|
| T3 | L3 |
| |
|
|
|
| BRN L1 T1 BLK M BLK | T2 | L2 |
|
| BLK |
|
|
|
|
|
|
|
|
|
| COMPRESSOR | T3 | L3 |
|
| BLK |
|
|
|
|
| LINE |
|
|
|
| CONTACTOR |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| GRN/YEL |
| |
|
|
|
|
|
|
|
|
| CONDENSER |
|
|
| |||
BLU |
|
| BLU | BLU |
|
|
| BLU | FAN MOTOR | M | BLK |
| WHT |
| |
|
|
|
|
|
|
| BRN |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| LOW PRESSURE |
|
|
| AIR COOLED ONLY |
|
|
|
|
|
| ||
|
|
| FAN SWITCH |
|
|
| BRN | BLU |
|
|
|
| |||
|
|
|
|
|
|
|
| GRN/YEL |
|
|
|
|
|
| |
BLK | M | BLK |
| WHT |
|
|
|
|
|
|
|
|
|
|
|
BLK |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
PANEL SPINNER OPTION |
| GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
| |
SEE FIG. 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BLK
GRN/YEL
WHT
|
|
| SOFT SERVE |
|
|
|
|
| 2014 | |
|
| A | PERSONALITY |
| NO | |||||
|
|
| BOARD |
|
|
|
|
|
| |
|
|
| SOFT SERVE |
|
|
|
|
| ||
|
| B | PERSONALITY | YES | ||||||
|
|
| BOARD |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| c |
|
|
|
|
| THERMOSTAT |
|
|
|
| ncefrigeration,IRCommercial |
| BLK | BLK |
|
| 140° OPEN | O.T. |
|
|
| |
|
| 012626 | 100° CLOSE |
|
|
|
| |||
|
| WHT |
| WHT | WHT |
| ||||
LINE | LOAD | M GRN/YEL |
| LEFT SYRUP HEATER |
|
| ||||
| BLK C |
|
|
|
|
|
| |||
| BLK | GRN | NO |
|
| GRN/YEL |
|
| ||
BLK |
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||
|
|
|
| THERMOSTAT |
|
|
|
| ||
LINE FILTER |
|
|
| 140° OPEN | O.T. |
|
|
| ||
|
|
| 100° CLOSE |
|
| WHT |
| |||
|
|
| WHT |
| WHT |
| ||||
SPINNER MOTOR WIRING |
|
|
| RIGHT SYRUP HEATER |
|
| ||||
FIG. # 1 |
|
|
| BLK |
|
|
|
| ||
|
|
|
| A | WHT |
|
| |||
|
| WHT |
|
|
|
|
|
| ||
|
|
| OPTIONAL HEATED SYRUP RAIL |
|
| |||||
NOTE: |
|
| GROUND FRAME SECURELY | |||||||
|
|
|
|
|
|
|
| |||
1. STATIC ELECTRICITY MAY CAUSE |
|
|
|
|
|
|
| |||
DAMAGE TO SOLID STATE COMPONENTS. |
|
|
|
|
|
|
| |||
ELIMINATE STATIC ELECTRICITY BY |
|
|
|
|
|
|
| |||
TOUCHING GROUNDED UNIT BEFORE |
|
|
|
|
|
|
| |||
HANDLING SOLID STATE COMPONENTS. |
|
|
|
|
|
|
| |||
2. RED WIRE ON RIBBON CABLES MUST BE |
|
|
|
|
|
|
| |||
CONNECTED TO PIN 1 AT EACH END. |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|