Operating Screen Descriptions

The fluorescent display located in the center of the control panel is normally blank during the daily operation of the machine. The display is activated when the SEL symbol or the Manager's Menu is selected. The display screen will also alert the operator of specific faults detected by the control.

Note: The displays illustrated in this section are those seen on the Models C709. The Model C717 displays may vary slightly.

Power Up Memory (Initializing)

The seven segment display should display “00” during the initializing sequence.

When the machine is powered, the control system will initialize to perform a system check. The screen will display “INITIALIZING”. There will be four types of data the system will check: LANGUAGE, SYSTEM DATA, CONFIG DATA, and LOCKOUT DATA.

Language Initialization

The UVC platform supports multiple languages by keeping specific strings in battery backed RAM. After power-up or a CPU reset, the strings are tested to see if the language strings are present and not corrupted. If the strings are present and not corrupted, initialization continues. Otherwise, the operator is prompted to select a language. While language strings are being checked for integrity, the following screen is displayed.

Initializing

Language

Note: If there is a language initialization fault, the machine will force a language selection prior to the initializing sequence. The standard menu LED's should light, as if it were in a menu. If a language has been selected, the unit is powered down, the machine should not ask for a language unless there is another language initialization fault. English is the factory default setting.

System Data

System data is protected separately from the rest of the data in memory. System data includes variables that change frequently such as the mode the machine is in, lockout status, serving counters, fault codes, and others. While System Data is being checked the following screen is displayed.

Initializing

System Data

If the System Data is corrupted, the machine is set to OFF, the serving counters are set to zero, and the faults are cleared. A “SYSTEM CRC ERR” fault is set and displayed on the VFD. An acknowledgement (SEL key) is required.

Configuration Data

Configuration data is separate from the rest of the data in the memory. Configuration data is information entered through operator and service menus. While Configuration Data is being checked the following screen is displayed.

Initializing

Config Data

If Configuration data is corrupted, all user and service settings are set to defaults. A “CONFIG CRC ERR” fault is set and displayed on the VFD. The system will continue to operate in its previous mode but according to default settings.

Lockout Data

Lockout data is protected separately from the rest of the data in the memory. While the Lockout Data is being checked, the following screen is displayed.

Initializing

Lockout Data

Important: To the Operator

18

Models C709 & C717

 

 

 

Page 22
Image 22
Taylor C709, C717 Operating Screen Descriptions, Language Initialization, System Data, Configuration Data, Lockout Data