Samson manual IMPORTANT NOTE Hanging the, Setting Up Your dB500a System, Permanent Installation

Models: dB500a

1 20
Download 20 pages 32.2 Kb
Page 13
Image 13
Permanent Installation

Setting Up Your dB500a System

Permanent Installation

The dB500a is logical solution for many fixed installations in live sound venues, discos, schools, houses of worship, con- vention centers and airport terminals to name a few. The enclosure is extremely versatile for installation as it can be hung in several different positions by using the ten Fly-points.

IMPORTANT NOTE: Hanging the

dB500a is serious business and therefore licensed and insured professional sound contractors only should perform such an installation.

Using the Fly-points

The dB500a features ten fly-points located in pairs below each of the five carry handles. By removing the handles you will have access to the threaded inserts that are compatible with a variety of standard M8 hard- ware. The dB500a’s ten fly points accept M8 rigging hardware like that available from ATM Flyware (www.atmflyware.com). M8-1.25, 16mm shoulder eyebolts (ATM Flyware part number, M8- 1.25x16EYE) can be used for hang- ing the enclosure. When using the eyebolts, be sure to use a 1.3 mm (0.05") thick flat-washer for 8 mm bolts against the insert, and a 2.6mm (0.09") thick lock-washer for 8 mm bolts between the flat-washer and the eyebolt.