Spinpoint M8-DVR OEM Product Manual REV 1.0
53
Word
Content
Description
3 1=Media Card Pass Through command feature set supported
2 1=Media serial number supported
1 1=SMART self-test supported
0 1=SMART error logging supported
85
7469h
Command set/feature enabled. (The default manufactu ring setting is as
below)
15 Obsolete
14 1=NOP command enabled
13 1=READ BUFFER command enabled
12 1=WRITE BUFFER command enabled
11 Obsolete
10 1=Host Protected Area feature set enabled
9 1=DEVICE RESET command enabled
8 1=SERVICE interrupt enabled
7 1=Release interrupt enabled
6 1= Look-ahead enabled
5 1=Write cache enabl ed
4 1=PACKET Co mmand feature set enabled (Should be cleared to 0)
3 1=Power Management feature set enabled
2 1=Removable Media feature set enabled
1 1=Security Mode f eature set enabled
0 1=SMART feature set enabled
86
BC41h
Command set/feature enabled.
15-14 Reserved
13 1=FLUSH CACHE EXT command supported
12 1=FLUSH CACHE command supported
11 1=Device Configuration Overlay features supported
10 1=48 bit address feature supported
9 Reserved
8 1=SET MAX securit y feature enabled by SET MAX SET PASSWOR D
7 1=Set Address Offset Reserved Area Boot, INCITS TR27:2001
6 1= SET FEATURES sub command required to spin-up after power-up.
5 1=Power-Up Standby feature set enabled
4 1=Removable media status notif ication feature set enabled
3 1=Advanced Power Management feature set enabled
2 1=CFA feature set enabled
1 1=READ/WRITE DMA QUEUED supported
0 1=DOWNLOAD MICROCODE command suppo rted
87
6123h
Command set/feature
default.
15 Shall be set to 0
14 Shall be set to 1
13 1=IDLE IMMEDIATE with UNLOAD FEATURE supported
12 Reserved for technical report
11 Reserved for technical report
10 1=URG bit supported for WRITE STREAM DMA EXT and WRITE STREAM
EXT
9 1=URG bit supported for READ STREAM DMA EXT and READ S TREAM
EXT
8 64-bit World wide name support ed
7 1=WRITE DMA QUEUED FUA EXT command supported
6 1=WRITE DMA FUA EXT an d WRITE MULTIPLE FUA EXT comman d
supported
5 General Purpose lo gging feature set supported
4 1=Valid CONFIGURATION STREAM command has been executed
3 1=Media Card Pass Through command feature set enabled
2 1=Media serial number is valid
1 1=SMART self-test supported
0 1=SMART error logging supported