SELECTIONI
Above 100cm(40 inch)

SELECTIONI

OF INSTALLATIONI I

PLACE

 

Indoor Unit

 

 

 

Install the unit at a place close to the wall facing the outside as

Top view

it is necessary to perform piping connection with the outdoor unit.

 

- It is effective to install the unit at a window side to ensure

 

uniform distribution of indoor temperature.

 

 

Install the unit at a place where there is no obstacle against the

 

wind around the air inlet and air outlet.

 

 

Install the unit horizontally at a stable, rigid place.

 

Above 50cm(20 inch)

 

 

(When installing the unit at a place subjected to

 

 

vibration, noise may occur.)

 

 

Avoid a place near the door which is frequented by people.

Avoid a place subject to direct sunlight.

Side view

 

Above 20cm(8 inch)

Outdoor Unit OF INSTALLATIONI I

Place free from the risk of combustible gas leakage.

Place which can bear the weight of the unit.

Place which can bear the fixing strength of the outdoor unit.

Avoid a place subject to oil (including machine oil).

Avoid a saline place.

Avoid a place subject to sulfide gas (hot spring zone).

(When installing the unit at such special environmental conditions, it may cause machine trouble. When it is unavoidable to use such places. It requires special maintenance.)

A place where the discharge air and noise of the outdoor unit do not disturb the neighborhood.

(Take special care not to cause any inconvenience to your neighbors when installing the unit on the borderline with your neighborhood.)

A place where strong wind does not head against the air outlet of the outdoor unit. (If a strong wind heads directly against the air outlet at the time of cool operation, a safety device can be operated.)

Do not install the outdoor unit at an unstable place such as outer wall of an apartment or building. The outdoor unit may fall down, causing severe personal or property damage or loss.

If there is any unavoidable reason to install the unit at such a place, take the following measures against the wind;

1.When installing the unit at a roadside concentrated with buildings, install it parallel with the road.

2.Install the unit so that the air outlet faces toward the wall at a place such as rooftop, which may be subjected to strong wind.

Wall

Air outletPLACEIndoor Unit

Strong wind

Roof top

The outdoor unit should be installed in accordance with the service space.

Above 15cm(6 inch)

 

 

Above 50cm

 

(20 inch)

Above 15cm(6 inch)

Space for piping

 

and wiring

Above 15cm(6 inch) Top view

Above 50cm (20 inch)

Space for piping

and wiring

Above 30cm(12 inch)

The air inlet faces toward the wall.

The air outlet faces toward the wall.

E-22