❏Fixing to the floor

INSTALLATIONI I METHOD

Indoor Unit ◆When using the leg holder of the indoor unit.

In order to install drain hose through wall, adjust height (max. 150mm/5.91 inch) of the indoor unit using leg holder.

Fixing to the floor

When using the leg holder of the indoor unit.

1.Lie down the unit on flat floor.

2.Insert the leg holders into screwed holes and then fasten them clockwise.

3.Turn the unit right and adjust horizontal line of it.

Mis-alignment of the unit can cause vibration and noise.

❏Fixing to the wall❏When using the anchor bolt Leg holder of the indoor unit

Fixing to the wall

When using fixing holder of the indoor unit.

1. Fix the holder using long screw bolts on wall.

2.Fix the unit using two screw bolts or four anchor bolts. (Size of the screw hole on the holder is ø 4.5mm/0.18 inch and size of the bolt is ø 6mm/0.24 inch).

Fixing holder of

the indoor unit

Outdoor Unit

When using the anchor bolt

1.Fix the unit on a flat, rigid floor using the anchor bolt. (Anchor bolt : M10 x 4 points - separately purchased)

When using the leg holder of the outdoor unit

1.Insert the foot holder (4EA).

2.Remove the nut fastened to the leg holder, and then insert the leg holder into the hole of the outdoor unit leg.

3.Fix the unit securely with the nut.

Anchor bolt fixing dimensions

 

 

A

 

 

Unit:mm(inch)

 

A

840(33 inch)

B

B

415(16.4 inch)

Nut

❏When using the leg holder of the outdoor unit Outdoor unit leg

Anchor bolt fixing dimensionsManual background Leg holder