Temperature and Humidity Ranges

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATING CONDITIONS

IF OUT OF CONDITIONS

 

Indoor temp: 16°C~32°C

- A safety device will stop continuously the

 

system functioning;

 

 

COOL

Indoor humidity: below 80%

- Condensation may occur on the indoor unit

 

Outdoor temp: 21°C~43°C

with risk to have either water blow off or drops

 

on the floor;

 

 

HEAT

Indoor temp: below 27°C

- A safety device will stop continuously the

 

Outdoor temp: 0°C~24°C

system functioning;

 

 

 

 

Indoor temp: 16°C~32°C

- A safety device will stop continuously the

 

system functioning;

 

 

DRY

Indoor humidity: below 80%

- Condensation may occur on the indoor unit

 

Outdoor temp: 18°C~43°C

with risk to have either water blow off or drops

 

on the floor;

 

 

POWER SUPPLY

Single phase rated voltage

220V-240V~50Hz

minimum and maximum limit

198V min.-264V max.

 

Any damage occurs out of condition specified cannot be covered by product warranty.

If the system works continuosly outside of conditions, its performace and reliability will be compromised.

Operating Recommendations

When you use your air conditioner, it is recommended that you read the following:

 

Topic

Recommendation

 

 

 

 

 

 

 

 

Heating capacity

The heat pump inside the air conditioner absorbs heat from outside air and brings itindoors.

 

 

If the temperature of the outside air drops, the air conditioner heats less. If the room is not warm

 

 

enough, use an additional heating appliance.

 

 

 

 

 

 

 

 

Warm air circulation

The air conditioner circulates warm air to heat your room. It will take some time to warm

 

 

the air in your room entirely after the air conditioner turns on.

 

 

Therefore, turn the air conditioner on in advance.

 

 

 

 

 

 

 

 

Frost

When you select the Heat mode, frost may form in the outdoor unit due to low temperature

 

 

and high humidity.

 

 

If this happens:

 

 

The heating operation is stopped.

 

 

The air conditioner defrosts automatically for about 7 minutes. After about 7 minutes,

 

 

the air conditioner starts operating again normally.

 

 

 

 

 

 

 

 

High indoor and

If both the indoor and outdoor temperatures are high when you select the Heat mode,

 

outdoor temperatures

the fan and the compressor of the outdoor unit may stop periodically.

 

 

This is normal; wait until the air conditioner turns on again.

 

 

 

 

 

 

 

 

Power failure

If a power failure occurs when the air conditioner is operating, the air conditioner will turn off.

 

 

When the power returns, the air conditioner will start up again automatically.

 

 

 

 

 

 

 

 

Protection mechanism

When the air conditioner is started immediately after being plugged in or stopped,

 

 

the normal operation starts up after 3 minutes for the reason of protection.

E-26

 

 

 

 

 

 

 

 

 

 

 

 