OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATIONAL TEMPERATURE

INDOOR HUMIDITY

IF OUT OF CONDITIONS

INDOOR

OUTDOOR

 

 

 

 

 

 

 

Condensation may occur on

COOLING

16˚C to 32˚C

15˚C to 43˚C

80% or less

the indoor unit with risk to have

either water blow off or drops on

 

 

 

 

 

 

 

 

the floor.

 

 

 

 

 

HEATING

27˚C or less

-5˚C to 24˚C

-

Internal protection triggers and

the air conditioner will stop.

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensation may occur on

DRYING

18˚C to 32˚C

15˚C to 43˚C

-

the indoor unit with risk to have

either water blow off or drops on

 

 

 

 

 

 

 

 

the floor.

 

 

 

 

 

The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition.

If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.

appendix _35

ENGLISH

AQ09E series_IB_E_30742_2.03.10.indd 35

2010-2-3 14:55:49

Page 35
Image 35
Samsung AQ09VBCNSER, AQ12EANSER, AQ09VBCXSER, AQ18EAXSER, AQ24EANSER, AQ24EAXSER, AQ09EANSER manual Operation Ranges, Cooling