OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATIONAL TEMPERATURE

INDOOR HUMIDITY

IF OUT OF CONDITIONS

INDOOR

OUTDOOR

 

 

 

 

 

 

 

Condensation may occur on

COOLING

18˚C to 32˚C

-5˚C to 43˚C

80% or less

the indoor unit with risk to have

either water blow off or drops on

 

 

 

 

 

 

 

 

the floor.

 

 

 

 

 

HEATING

27˚C or less

-20˚C to 24˚C

-

Internal protection triggers and

the air conditioner will stop.

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensation may occur on

DRYING

18˚C to 32˚C

-5˚C to 43˚C

-

the indoor unit with risk to have

either water blow off or drops on

 

 

 

 

 

 

 

 

the floor.

 

 

 

 

 

The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition.

If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.