Optional accessories
The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.
Insulated Assembly | Insulated Assembly | Insulated Assembly Pipe, | Insulated Assembly Pipe, Ø15.88/ | PE T3 Foam |
| Drain Plug (1) | |
Pipe, Ø6.35mm (1) | Pipe, Ø9.52mm (1) | Ø15.88mm (1) | Ø19.05mm (1) | Tube | Vinyl Tapes (2) | ||
AQ | |||||||
30/32 | 36 | 30/32 | 36 | Insulation (1) |
| ||
| ENGLISH | ||||||
|
|
| 150mm |
|
| ||
|
|
|
|
|
| ||
|
|
| Outdoor(Ø19.05mm) Indoor(Ø15.88mm) |
|
|
| |
Rubber Legs (4) | Pipe Clamps A (3) | Pipe Clamps B (3) | Cement Nails (6) | M4 x 25 Tapped | Drain Hose, | Putty 100g (1) | |
Screws (6) | length 2m (1) | ||||||
|
|
|
|
| |||
Foam |
|
|
|
|
|
| |
Insulation(1) |
|
|
|
|
|
|
• If these accessories are supplied, they will be in the accessory box.
Tools required for installation
General Tools
• Vacuum Pump(Backward flowing prevention) | • Manifold Gauge | • Stud Finder | ||
• Torque Wrench | • Pipe Cutter | • Reamer | • Pipe Bender | • Spirit Level |
• Screw Driver | • Spanner | • Drill | • L Wrench | • Measuring Tape |
Tools for test operations
• Thermometer | • Resistance Meter • Electroscope |
Fixing the installation plate
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
• Right (A) |
| Direction of pipe |
|
• Left (B) |
|
|
|
• Underside_right (C) | A |
| B |
• Rear_right or left (D) |
| ||
| D | D |
C
1.Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.
(Unit : mm)
| 67 |
156 | 364 |
| |
| 34.5 |
19.5 | 64.5 |
•Make sure to drill only one hole after choosing the direction of the pipe.
29