Samsung AQV24UGDNEUR, AQV09PWCNEUR, AQV09UGFXEUR manual Extend the assembly cable if necessary

Models: AQV09UGFNEUR AQV09PWCNEUR AQV10UWFNEUR AQV24UGDNEUR AQV09UGFXEUR AQV10UWFXEUR AQV09PWCNCEE AQV24UGDXEUR AQV12UGFNEUR AQV18UGDXEUR AQV12UGFXEUR AQV18UGDNEUR

1 43
Download 43 pages 50.37 Kb
Page 29
Image 29

• For the terminal block wiring, use a wire with a ring terminal socket only.

Regular wires without a ring terminal socket may become a fire hazard due to overheating of the electrical contact during a wiring work.

When you install the unit, make first refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, first disconnect electrical cables, then refrigerant connections.

If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15(09/12)/20(18/24) meters.

1.Extend the assembly cable if necessary.

Do not connect two or more different cables to extend the length.

It may cause fire.

2 . Open the front grille.

3 . Remove the screw securing the connector cover.

4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below)

• Each wire is labeled with the corresponding terminal number.

5 . Pass the other end of the cable through the 65mm hole in the wall.

6 . Close the connector cover by tightening the screw carefully.

7 . Close the front grille.

8 . Remove the terminal board cover on the side of the outdoor unit. 9. Connect the cables to the terminals as seen in the picture.

• Each wire is labeled with the corresponding terminal number.

Indoor unit

 

 

18/24

 

 

09/10/12

 

Indoor unit

Indoor unit

 

 

 

 

 

 

 

1(L)

2(N)

F1

F2

N(1)

1

2

 

 

 

 

N(1)N1

1

2

1(L)

2(N)

F1

F2

 

 

 

 

Outdoor unit

N(1) 1 2

 

 

F1

F2

 

N(1)

1

2

L

N

Outdoor unit

 

 

 

Outdoor unit

 

 

 

 

The appearance of the unit may be different from the diagram depending on the model.

• End of the wire must be circular.

• Also circular terminal must be matched with screw size in terminal black.

After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.

Screws on terminal block must not be unscrewed with the torque less than 12kgf•cm.

10.Connect the grounding conductor to the grounding terminals.

11.Close the terminal board cover by tightening the screw carefully.

• In Russia and Europe, consult with the supply authority to determine the supply system impedance before

installation.

• Connect the wires according to color codes, referring to the wiring diagram.

• The power cable and the interconnection cable should be selected according to the specification in page 28.

ENGLISH

29

Vivaldi MAX EUR_AQV09&12U@@ IB&IM_33988A_EN-5.indd 29

2014/12/11 18:24:27

Page 29
Image 29