Temperature and Humidity Ranges

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATING CONDITIONS

IF OUT OF CONDITIONS

 

Indoor temp: 16°C~32°C

- A safety device will stop continuously the system

COOL

Indoor humidity: below 80%

functioning;

 

- Condensation may occur on the indoor unit with

 

Outdoor temp: -10°C~43°C

risk to have either water blow off or drops on the

 

 

floor;

HEAT

Indoor temp: below 27°C

- A safety device will stop continuously the system

Outdoor temp: -15°C~24°C

functioning;

 

 

Indoor temp: 16°C~32°C

- A safety device will stop continuously the system

DRY

Indoor humidity: below 80%

functioning;

 

- Condensation may occur on the indoor unit with

 

Outdoor temp: -10°C~43°C

risk to have either water blow off or drops on the

 

 

floor;

POWER SUPPLY

Single phase rated voltage

220V-240V~50Hz

minimum and maximum limit

198V min.-264V max.

 

Any damage occurs out of condition specified cannot be covered by product warranty.

If the system works continuosly outside of conditions, its performace and reliability will be compromised.