Information about refrigerant

Important information: regulation regarding the refrigerant used

This product contains fluorinated greenhouse gases.Do not vent gases into the atmosphere.

CAUTION

If the system contains 5 tCO2e or more of fluorinated greenhouse gases, it must be checked for leakage at least once every12 months, according to regulation No. 517/2014. This activity must be covered by qualified personnel only. In the case of the situation above, the installer (or authorized person with responsibility for final check) must provide a maintenance book, with all the information recorded, according to REGULATION (EU) No. 517/2014 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on fluorinated greenhouse gases.

This indoor unit can be connected to an R-32 or R-410A outdoor unit.

Refrigerant type

GWP value

R-32

675

R-410A2088

GWP: Global Warming Potential

Calculating tCO2e : kg x GWP/1000

Maintenance and Cleaning