Step1.4 Drilling a hole through the wall

Before fixing the installation plate to a wall and then fixing the indoor unit to the installation plate, a window frame, or a gypsum board, you must determine the position of a hole (with 65 mm inner diameter) through which the pipe bundle (consisting of power and communication cables, refrigerant pipes, and drain hose) will pass and then drill that hole.

1.Determine the position of a 65 mm hole in consideration of the possible directions of the pipe bundle and the minimum distances between the hole and the installation plate.

Left

Right

 

Rear right or left

Bottom right

<Possible directions of the pipe bundle>

CAUTION

If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

Pipe bundle hole

<Minimum distances between the hole and the

installation plate>

 

 

 

 

(Unit : mm)

 

 

 

 

 

 

Model

A

B

C

 

D

 

 

 

 

 

 

✴✴09✴✴LN/RC

36

60

65

 

36

 

 

 

 

 

 

✴✴09✴✴PF/SG

36

120

81

 

36

✴✴12✴✴

 

 

 

 

 

 

 

 

 

 

 

 

✴✴18✴✴LN/RC

36

190

81

 

36

 

 

 

 

 

 

✴✴18✴✴PF/SG

33

110

110

 

33

✴✴24✴✴

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

2.Drill the hole.

CAUTION

Be sure to drill only one hole.

Make sure that the hole slants downwards so that the drain hose slants downwards to drain water well.

Wall

Drain hose

Indoor unit

<The hole slants downwards>

Step1.5 Taping the pipes, cables, and drain hose

1.Wrap foam insulation on parts without insulation on the ends of the refrigerant pipes, as shown in the figure. This wrapping minimises condensation problem.

Insulation

Refrigerant pipes

2.Wind the refrigerant pipes, power cable, communication cable and drain hose with vinyl tape to make a pipe bundle.

 

Refrigerant pipes

Installation plate

(assembly pipe)

 

Vinyl tape

 

Power and communication cables

 

(assembly cable)

 