Step 4.3 Performing final check and trial operation

1.Check the following:

Strength of the installation site

Tightness of pipe connection to detect gas leak

Electric wiring connection

Heat-resistant insulation of the pipe

Drainage

Grounding conductor connection

Correct operation (Take the following steps.)

2.Press the (Power) button on the remote control to check the following:

The indicator on the indoor unit lights up.

The airflow blade opens and the fan gears up for operation.

3.Press the (Mode) button to select Cool or Heat mode. Then take the following sub-steps:

In Cool mode, use the Temperature button to set the set temperature to 16 °C.

In Heat mode, use the Temperature button to set the set temperature to 30 °C.

Check whether, approximately 3 to 5 minutes later, the outdoor unit starts, and a cool or warm air blows out.

After12 minutes of stationary condition, check the indoor unit air treatment.

4.Press the (Air swing) button to check whether the airflow blades work properly.

5.Press the (Power) button to stop the trial operation.

Pumping down refrigerant

Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit. This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere.

1.Shut off the liquid valve with the Allen wrench.

2.Turn on the air conditioner in cooling with fan operating at high velocity. (Compressor will immediately start, provided 3 minutes have elapsed since the last stop.)

3.After 2 minutes of operation, shut the suction valve with the same wrench.

4.Turn off the air conditioner and switch mains supply off.

5.Disconnect tubing. After disconnection, protect valves and tubing ends from dust.

CAUTION

Compressor damage may occur if the compressor is run at a negative suction pressure.

Pumping down for removing the product

1.Turn on th air conditioner and select Fast Cool mode.

2.Let the compressor run for more than 5 minutes. If the compressor does not operate for more than 5 minutes due to protection control, wait about 2 minutes, and then carry out the next procedure.

3.Release the valve caps on High and Low pressure side.

4.Use L-wrench to close the valve on the high pressure side.

5.After approximately 1 minute, close the valve on the low pressure side.

6.Stop operation of the air conditioner by pressing the (Power) button on the indoor unit or remote control.

7.Disconnect the pipes.

 

1

 

1 minute

Liquid service port

Gas service port

<High pressure>

<Low pressure>

2

Off

English 45

Installation

DB68-06031A-01_A5.indd 45

4/18/2017 9:00:06 AM

Page 46
Image 46
Samsung AR18KPFNDWKXSG, AR24KPFNDWKNSG, AR18KPFNDWKNSG Performing final check and trial operation, Pumping down refrigerant

AR18KPFNDWKNSG, AR18KPFNDWK/SG, AR12KPFNDWK/SG, AR24KPFNDWKNSG, AR12KPFNDWKXSG specifications

Samsung's AR series air conditioners, including models AR12KPFNDWKNSG, AR24KPFNDWK/SG, AR12HPFSDWK/SG, AR12KPFNDWKXSG, and AR24KPFNDWKNSG, represent a perfect blend of advanced technology, efficiency, and design, making them a vital component of modern home environments.

One of the standout features of these models is Samsung's Digital Inverter technology. This state-of-the-art system optimizes energy consumption by automatically adjusting the compressor speed depending on the cooling demand. As a result, these air conditioners not only provide powerful cooling when it's needed but also operate quietly and maintain energy efficiency, resulting in lower electricity bills.

Another notable characteristic is the Fast Cooling mode, which allows for rapid temperature adjustments. This is particularly advantageous during the sweltering summer months when immediate relief is desired. The AR series can quickly lower temperatures to provide comfort as soon as you enter the room.

These models also come equipped with Samsung's advanced filtration technology, which plays a significant role in maintaining indoor air quality. The air conditioners are designed with a multi-layer filtration system that traps dust, allergens, and other pollutants, creating a cleaner and healthier environment for occupants. This feature is increasingly essential, particularly for those with allergies or respiratory concerns.

The design of the AR series is sleek and modern, ensuring that they fit seamlessly into any interior decor. The front panel is smooth and simple, often available in neutral colors that allow it to blend effortlessly with various room styles. Furthermore, the compact form factor of these units makes them easy to install without compromising valuable floor space.

In terms of control, these air conditioners are user-friendly. They often come with a remote control for convenient operation from anywhere in the room, as well as smart features that enable control via smartphone apps. This compatibility with smart home systems provides added convenience for tech-savvy users.

Moreover, the models are designed with durability in mind. High-quality components and a robust build ensure that these air conditioners are built to last, handling the rigors of everyday use while minimizing maintenance needs.

In summary, the Samsung AR12KPFNDWKNSG, AR24KPFNDWK/SG, AR12HPFSDWK/SG, AR12KPFNDWKXSG, and AR24KPFNDWKNSG models epitomize modern air conditioning technology. With their efficient performance, advanced filtration, user-friendly controls, and stylish design, they cater to contemporary consumer needs while ensuring comfort and satisfaction.