Samsung AW0610A, AW0510D, AW0510B Checkpoints prior to installation, Installation instructions

Models: AW0600 AW0510A AW0610A AW0510B AW0510D

1 17
Download 17 pages 49.01 Kb
Page 12
Image 12
Installation

Installation

22" to 36"

12 7/8" min

Before installation, please read the INSTALLATION instructions, then follow the procedures in order after considering the installation area and drain hose.

CAUTION

The manufacturer does not assume responsibility for accident or injury caused by an incorrectly installed air conditioner. If you are unsure about installation, contact an installation specialist.

Checkpoints prior to installation

1Check the cabinet and front grille of the unit for any defects such as scratches.

2Be sure to check the power supply.

- Refer to the specifications on the label attached to the unit.

Installation instructions

1Electrical Requirements For personal safety:

This appliance must be properly grounded.

Do not, under any circumstances, cut or remove the third grounding prong from the power cord.

We recommend that you do not use an extension cord or an adapter plug with this appliance.

Do not change the plug on the power cord of this appliance.

Follow national electrical codes or local codes and ordinances.

 

115V

230V/208V

230V/208V

230V/208V

15 AMP circuit

20 AMP circuit

15 AMP circuit

30 AMP circuit

"parallel" type

"perpendicular" type

"tandem" type

"tandem" type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the electric supply provided does not meet the above specifications, call a licensed electrician.

Aluminum house wiring may pose special problems - consult a qualified electrician.

This unit requires a separate circuit, serving only this appliance.

2Window Requirements

Standard double-hung window with actual opening width of 22" to 36". The installation will need to be modified for windows other than

the standard double-hung type.

Clear vertical opening of 12 7/8" minimum, from bottom of sash to sill.

Install the air conditioner in a window where there will be enough clearance around the cabinet to allow ample circulation of air through the unit.

Note All supporting parts should be secured to firm wood, masonry or metal.

E-12

Page 12
Image 12
Samsung AW0610A, AW0510D, AW0510B, AW0510A, AW0600 manual Checkpoints prior to installation, Installation instructions