1Preparations
Manual Lamp (Backlight) Control
z
z
Function
The "Manual Lamp(backlight)" of a product can be changed using a PC. Get "LampValue" Status
Header | Command |
|
|
0xAA | 0x58 |
|
|
ID
Data length
0
Checksum
z
z
Set "LampValue"
Header | Command | ID | Data length | Data | Checksum | |
|
|
|
| |||
0xAA | 0x58 | 1 | "LampValue" | |||
|
| |||||
|
|
|
|
|
|
"LampValue" : Manual Lamp value to be set on a product. (0 ~ 100) Ack
Header | Command |
|
|
0xAA | 0xFF |
|
|
ID
Data length | Ack/Nak | Val1 | |
|
|
|
|
3 | ‘A’ | 0x58 | "LampValue" |
|
|
|
|
Checksum
"LampValue" : Manual Lamp value to be set on a product. (0 ~ 100)
zNak
Header | Command |
|
|
0xAA | 0xFF |
|
|
ID
Data length | Ack/Nak | Val1 | |
|
|
|
|
3 | ‘N’ | 0x58 | "ERR" |
|
|
|
|
Checksum
"ERR": A code showing what error has occurred.
0 : Check Sum Error
1 : Not Supported Command
1 Preparations 40