ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.
ERROR ITEMS AND DIAGNOSTIC CODES
An occurrence of an Error will make a sound of error melody for 5sec and con tinuously show one of the Error Displays from the following errors.
Error Display | Trigger | Action Taken | ||
|
| |||
LED | LCD | |||
|
| |||
|
|
|
| |
tS |
| The Thermistor | Check for : | |
|
| - Clogged lint screen | ||
|
| resistance is very low or | ||
|
| - Restricted vent system. | ||
tO |
| high. | ||
| - Check Thermistor resistance. | |||
|
| |||
|
|
|
| |
|
|
| Check for : | |
|
| Running the dryer with | - Close the door, and run the | |
dO |
| dryer | ||
| door open | |||
|
| - Loose or open wire terminals | ||
|
|
| ||
|
|
| in Door sense circuit. | |
|
|
| Check for : | |
dF |
| Invalid state for more | - Loose or open wire terminals | |
| than 256 milliseconds | in Door | ||
|
| |||
|
|
| sense circuit. | |
|
| Invalid state of key | Check for : | |
bE |
| - Display PCB key circuit short | ||
| circuit short for 75secs | |||
|
| or not | ||
|
|
| ||
|
|
|
| |
|
|
| Check for : | |
od |
| Invalid Dry time in | - Sensor bar Open | |
| excess Dry time | - Using Adjust time Up exces- | ||
|
| |||
|
|
| sively | |
|
| Invalid heating Temp in | Check for : | |
hE |
| - Restricted vent system. | ||
| running the dryer | |||
|
| - Check Thermistor resistance. | ||
|
|
| ||
|
|
|
| |
Et |
| Invalid state of Eeprom | Check for : | |
| communication | - PCB on Eeprom circuit | ||
|
| |||
|
|
|
| |
|
|
| Check for : | |
|
| Invalid power source | - Not using regular power | |
FE |
| source frequency | ||
| Frequency | |||
|
| - Invalid power frequency sense | ||
|
|
| ||
|
|
| circuit |