TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

GAS MODEL

Radiant Sensor(10RS)

Resistance value < 1 Ω

If resistance is infinite, replace Radiant sensor

Igniter(101D)

Resistance value 40~400 Ω

If resistance is infinite, replace Igniter

Gas Valve(25M01A)

Valve 1-2 : Resistance value 1.2K Ω

Valve 1-3 : Resistance value 0.5K Ω

Valve 4-5 : Resistance value 1.2K Ω If resistance is infinity, replace Valve

Thermostat (60T21 Hi-Limit)230F-50F Resistance value < 1 Ω

If resistance is infinity, replace Thermostat

Technical_information-02365B.ind9 9

2008-06-25 ¿ÀÈÄ 5:24:27

Page 9
Image 9
Samsung DV338 Radiant Sensor10RS, Igniter101D, Gas Valve25M01A, Thermostat 60T21 Hi-Limit230F-50F Resistance value 1 Ω