TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

GAS MODEL ONLY

Radiant Sensor(10RS)

Gas Valve(25M01A)

Resistance value < 1 Ω

Valve 1-2 : Resistance value 1.2K Ω

If resistance is infinite, replace Radiant sensor

Valve 1-3 : Resistance value 0.5K Ω

 

Valve 4-5 : Resistance value 1.2K Ω

 

If resistance is infinity, replace Valve

Igniter(101D)

Resistance value 40~400 Ω

If resistance is infinite, replace IgniterThermostat (60T21 Hi-Limit)230F-50FResistance value < 1 Ω

If resistance is infinity, replace Thermostat