TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

No

Problem

What To Do

 

 

 

 

 

 

If the igniter does not heat up, remove power and using an

 

 

ohmmeter, check the following:

 

 

 

Open flame sensor

 

8

The igniter does not

Open igniter

 

glow

Shorted booster coil

 

 

 

 

 

Open wiring

 

 

 

Bad motor switch ( Neutral supply)

 

 

 

No power from control ( L1 supply)

 

 

 

If the igniter heats up but the main burner flame is not ignited,

 

 

remove power and using an ohmmeter, check the following:

9

Igniter glows - No gas

Open secondary coil

 

ignition

Open holding coil

 

 

 

 

 

Open wire harness

 

 

 

Stuck flame sensor (Stuck closed)

 

 

 

If a normal ignition takes place and after a short while the flame goes

 

 

out, check for the following:

 

 

The gas is ignited but

Radiant sensor contacts opening prematurely.

 

10

the flame goes out

Weak gas valve coil may open when stressed by higher Temps.

 

 

Weak Hi-Limit

 

 

 

Poor venting

 

 

 

Bad drum seals

 

 

 

Lint filter is not clean.

 

 

 

Restriction in exhaust.

 

 

 

Outside exhaust hood damper door stuck closed.

 

Improper drying

Exhaust too long, too many elbows, flex ductwork installed.

11

clothes wrinkled

Poor intake air available for the dryer.

 

Rough texture long

Incorrect tumbler speed. Tumbler belt slipping.

 

dry time

Blower impeller bound; check for foreign material in blower area.

 

 

Customer overloading dryer.

 

 

 

Check clothing labels for fabric content and cycle selected.

 

 

Clothes too wet due to insufficient spin out by

washer.

 

 

Thumping Check for loose tumbler baffle, rear

tumbler roller(s)

 

 

 

worn or misaligned, out-of-round tumbler or high weld seam on

 

 

 

tumbler.

 

 

 

Ticking Check for loose wire harness or object caught in blower

12

Noisy and/Or

wheel area.

 

Vibration

Scraping Check for front or rear bulkhead felt seal out of

 

 

 

position or worn tumbler front bearings.

 

 

 

Roaring Check for blower wheel rubbing on blower housing or

 

 

 

bad motor bearings.

 

 

 

Popping or squealing sound. Check for a sticky or frayed belt.

 

 

 

 

 

 

 

 

7

 

(Technical)DV431AEP-02365F-01_EN.indd 7

2012-04-27 �� 10:22:51

Page 7
Image 7