ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Continuous Run Mode

Power On state

 

Mixed Load Bell +Dry Level(DV431) or

(Normal user mode)

 

Wrinkle Prevent + Time(DV231) 7 SEC

 

 

 

Continuous Run Mode

How to enter:

-Press Mixed Load Bell +Dry Level(DV431) or Wrinkle Prevent + Time(DV231) for 7 sec during Power On State (normal user mode).

-Once in Continuous Run Mode, display “CC” for 1 sec and the remaining time for 2 sec in turns.

-The previous cycle will restart during Continuous Run Mode until the mode is deactivated.

-During Continuous Run Mode, press Mixed Load Bell +Dry Level(DV431) or Wrinkle Prevent + Time(DV231) for 7 seconds to go back to normal user mode.

Data Display Mode (DV431 only)

How to Enter:

-With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a beeping sound .

-If not pressed any keys for 5 minutes, it will be set back from Data Display Mode

-If pressing AdjustUp Key in this mode, Display Mode will be incresed.

-If pressing AdjustDown Key in this mode, Display Mode will be decresed.

Definition of Data Display Mode:

-Display Mode 1 : Temperature data

-Display Mode 2 : Average Touch Sensor data for 1 minute

-Display Mode 3 : Average Temperature data for 1 minute

4

(Technical)DV431AEP-02365F-01_EN.indd 4

2012-04-27 �� 10:22:51

Page 4
Image 4
Samsung DV431AEP/XEU manual Continuous Run Mode, Data Display Mode DV431 only, Definition of Data Display Mode