FACTORY & ELECTRONIC ADJUSTMENT | VER1.0 |
B.Bright level center block definition: Pattern set = Pattern name =
Background color = 0 Foreground color = 25
According to the
from Pen 25 = R: 614, G: 614, B: 614
614 (output amplifier)/1024 (total amplifier)=60%, therefore the 60% is the 60 IRE white output pattern.
(5)Flatly place the Minolta Color Analyzer’s Photo Detector in contact with the center of the PDP screen.
2.2RGB Mode Color Temperature Adjustment Procedure:
(1)With the PDP’s RGB input connected to Chroma
(2)Press the Left/Right Button to switch between the Bias (R, G, B) and Gain (R, G, B) values. Use the Up/Down Buttons to change the Bias and Gain Values.
(3)5400K dark level center block adjustment procedure:
A.Select
B.Select
C.Select
D.Repeat steps A, B and C until the following final values are obtained:
x= 335±30
y= 343±30
Y = 0.5±0.1 FL
(4)5400K bright level center block adjustment procedure: (Please set the Chroma
A.Select
B.Select
C.Select
D.Repeat steps A, B and C until the following final values are obtained:
x= 335±30
y= 343±30
Y = 30±1 FL
(5)Upon completion of Steps 3 and 4 above, press the FAV.SET key for the next Color Temperature setting (5400→6500D→9300→13800).