FACTORY & ELECTRONIC ADJUSTMENT | VER1.0 |
For each color temperature setting, please repeat Steps 3 and 4 above but replace the x and y settings with the following values:
a.6500D: x = 313, y = 329 for both Dark and Bright Level Settings
b.9300K: x = 285, y = 295 for both Dark and Bright Level Settings
c.13800K: x = 260, y = 275 for both Dark and Bright Level Settings
For these 3 Color Temperatures (6500D, 9300K and 13800K), adjust the Dark and Bright Levels to the following Y values:
a.Dark level Y = 0.5±0.1 FL
b.Bright level Y = 30±1 FL
(6)Once all 4 Color Temperatures have been adjusted, skip through the Component Color Temperatures and completely exit the Factory Adjustment Menu.
3.1
(1)Turn on the Color Analyzer (Minolta, Model =
(2)Switch the PDP input to Component1 mode and press the “Recall” key on the remote control to have the PDP set recalled back to default factory settings.
(3)Set up the Video Pattern Generator (ie. SENCORE
A. Dark Level Center block definition:
a.Signal Type: Component
b.Format: 1080i
c. Pattern = WINDOW 1 14 IRE
B.Bright Level Center block definition:
a.Signal Type: Component
b.Format: 1080i
c. Pattern = WINDOW 2 60 IRE
(4)Connect the PDP Component1 input to the
(5)Flatly place the Minolta Color Analyzer’s Photo Detector in contact with the center of the PDP screen.
3.2Component Mode Color Temperature Adjustment Procedure:
(1)Set the
select the Color Temperature Adjustment option. Using the FAV.SET key skip through all the DVI and RGB Color Temperatures until you reach the 5400K Component Color Temperature OSD.
(2)Press the Left/Right Button to switch between the Bias (R, G, B) and Gain (R, G, B) values. Use the Up/Down Buttons to change the Bias and Gain Values.