4. Test Information
Test Parameters
| Parameters | Actual | Parameters | Actual |
|
|
|
|
|
| Ambient temperature | 25.8 (℃) | Test Voltage | 230V |
|
|
|
|
|
| Total harmonic distortion | 1.2 | Test Frequency | 50Hz |
|
|
|
|
|
| Test Instrumentations |
|
|
|
|
|
|
|
|
| Test instrumentation | Model name | Manufacture | Expire date of Calibration |
|
|
|
|
|
| Power meter | WT1800 | Yokogawa | |
|
|
|
|
|
| Power Source | 6560 | Chroma | |
|
|
|
|
|
|
|
|
|
|
Set-up and circuit for electrical testing
4. Reference for test method
-EN 62301 ed. 2.0; Household electrical appliances – Measurement of standby power
-IEC 62323 ed. 1.0; Desktop and notebook computers – Measurement of energy consumption
-ISO 7779 :2010; Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment
-US EPA "Test Method for calculating the Energy efficiency of single voltage External
-ISO 9296:1988; Acoustics - Declared noise emission values of computer and business equipment
-
-
Page 2 / 2