2.4Sequence of events to reach the mode where the equipment automatically change modes ( It is necessary to write the taken time to reach to the mode )

N/A

2.5Any notes regarding the operation of the equipment

N/A

2.6 Instrumentation

Test instruments which were used in the test are as follows;

 

Test instrumentation

 

 

 

Model name

 

 

Manufacturer

 

 

Serial or Firmware

 

 

Calibration

 

 

 

 

 

 

 

 

(No./Ver.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Date

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stopwatch

 

 

PC90

 

Time Art

 

TPST003

 

1st Apr. 2015

 

Power meter

 

 

WT1806

 

Yokogawa

 

0GAA-B04817

30th Mar. 2015

 

 

 

 

 

 

 

 

 

 

Power Source

61605

 

 

Chroma

 

0GAA-B05037

7th Oct. 2015

2.7 Measurement method used

-Measurement condition_1) Picture : no input load, 2) Sound : no input load.

-The EUT was placed into off mode using the hard switch

-The EUT was placed into the mode allowed to stabilize for 30 minutes.

-The stability is established where the power difference between the two comparison periods divided by the time difference of the mid-points of the comparison periods has a slope of less than 10 mW/h.

-The accumulated power consumption was measured for 10 minute.

2.8Set-up and circuit for electrical testing ( Insert the picture or diagram of the test configuration )

3.Normal Standby mode

3.1Test result

 

Test date

 

N/A

 

Power Consumption (W)

 

Condition A

Condition B

 

 

 

(rounded to the 1st decimal place)

 

 

 

 

 

 

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)Condition A : Any condition providing only reactivation function, or providing only a reactivation function and mere indication of enabled reactivation function

2)Condition B : Any condition providing only information or status display, or providing only a combination of reactivation function and information or status display