4th Jan. 2016

 

Test instrumentation

 

 

Model name

 

 

Manufacturer

 

 

Serial or Firmware

 

 

Calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(No./Ver.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Date

 

 

 

 

 

 

 

 

 

 

 

 

 

Stopwatch

 

PC90

 

Time Art

 

TPST003

 

1st Apr. 2015

 

 

 

 

 

 

 

 

 

 

Power meter

 

WT1806

 

Yokogawa

 

0GAA-B04817

30th Mar. 2015

 

Power Source

61605

 

 

Chroma

 

0GAA-B05037

7th Oct. 2015

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.8Measurement method used

-Measurement condition_1) Picture : no input load, 2) Sound : no input load.

-Deactivate all other network ports that are not under test.

-Ensure that the EUT does not perform a main function and wait for 20 minutes, So that the EUT able to go into the networked mode.

-The EUT standby mode power consumption was monitored for a further period of 5 minutes.

The variation in power consumption over this period is 5%, so the maximum reading of NTW standby mode power as measured by the power analyzeris recorded as the test result

1.9 Set-up and circuit for electrical testing ( Insert the picture or diagram of the test configuration )

2. Off mode

2.1Test result

Test date

Power Consumption (W)

(rounded to the 1st decimal place)

0.0

2.2 Test parameters

parameters

 

 

Actual

 

Limit

 

parameters

Actual

Limit

 

 

 

 

 

 

 

 

 

 

Ambient temperature ( )

26.0

23±5

 

Test voltage (V)

230

230±2.3

 

 

 

 

 

 

 

 

 

 

Test frequency (Hz)

 

50

50±0.5

 

Total harmonic distortion

1.42

2

 

 

 

 

 

 

 

(%)

 

 

 

 

 

 

 

 

 

 

 

 

Crest factor

1.40

1.34~1.49

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.3 Description of how the appliance mode was selected or programmed Standby mode was selected by turning off by remote server

3

Page 3
Image 3