Introduction

1

Power control

0x11

0~1

 

 

 

 

2

Volume control

0x12

0~100

 

 

 

 

3

Input source control

0x14

-

 

 

 

 

4

Screen Mode control

0x18

-

 

 

 

 

5

Screen Size control

0x19

0~255

 

 

 

 

6

PIP on/off control

0x3C

0~1

 

 

 

 

7

Auto adjustment control

0x3D

0

 

 

 

 

8

Video wall Mode control

0x5C

0~1

 

 

 

 

9

Safety Lock

0x5D

0~1

 

 

 

 

-ID should show hexadecimal value of assigned ID, but ID 0 should be 0xFF.

-Every communication will be made in hexadecimals and Checksum is the sum of all remainings. If it exceeds two digits,for example, it is 11+FF+01+01=112, discard the number in the first digit like below.

example)PowerOn&ID=0

Header

command

 

DATA

DATA 1

 

 

 

ID

Length

 

CheckSum

0xAA

0x11

 

1

Power

 

 

 

 

 

Header

command

 

DATA

DATA 1

 

 

 

ID

Length

 

12

0xAA

0x11

 

1

1

 

 

 

 

 

 

 

If you want to control every mechanism connected with Serial Cable regardless of its ID, set ID part to "0xFE" and send commands. At the time, each product will follow commands but it will not respond with ACK.

Power Control

Function

Personal Computer turns TV / Monitor power ON/OFF.

Get Power ON/OFF Status

 

Header

 

command

ID

 

DATA Length

CheckSum

 

 

 

 

 

 

 

 

 

0xAA

 

0x11

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Set Power ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

command

 

 

 

DATA

DATA

 

 

 

 

 

 

ID

 

Length

 

 

CheckSum

 

0xAA

 

0x11

 

 

1

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

Power : Power code to be set on TV / Monitor

1 : Power ON

0 : Power OFF