Temperature and Humidity Ranges

The following table indicates the temperature and humidity ranges within which the air conditioner can be used.

If the air conditioner is used at... Then...

High temperatures

The automatic protection feature may

 

 

be triggered and the air conditioner

 

 

stopped.

 

 

 

Low temperatures

A water leak or some other malfunction

 

 

may occur if the heat exchanger

 

 

freezes.

 

 

 

High humidity levels

Water may condense on and drip

 

 

from the surface of the indoor unit if it

 

 

is used for long periods.

 

 

 

 

 

 

 

 

Mode

Outdoor Temperature

Indoor Temperature

Indoor Humidity

 

 

 

 

Heating

0°C to 24°C approx.

27°C or less.

-

Cooling

21°C to 43°C approx.

18°C to 32°C approx.

80% or less

Drying

18°C to 43°C approx.

18°C to 32°C approx.

-

If the heating operation is used at below 0°C(outdoor temperature) then, it does not heat as its full capacity.

If the cooling operation is used at over 33°C(indoor temperature) then, it does not cool as its full capacity.

Power Supply

AC 220-240V~, 50Hz

 

 

 

Capacity

COOL

25800BTU/h

 

 

HEAT

29800BTU/h

 

 

 

 

Current

COOL

12.0A

 

 

HEAT

12.5A

 

 

 

 

Input Power

COOL

2600W

 

 

HEAT

2800W

 

 

 

 

Max Current

COOL

15.0A

 

 

HEAT

19.0A

 

 

 

 

Refrigerant

R-22 / 2150g

 

 

 

Current and input power are measured according to ISO standard and max current is measured according to IEC standard.