ADJUSTING THE FREEZER DRAWER LEVEL
Adjustment part
Freezer Drawer
1. Locate the Unscrew the four Phillips screws ( 2 ) slightly to loosen the door.
1 2
2.Loosen the controller screw( 3 ) with a Phillips screwdriver.
3
3. Find the best level to align the door slope.
Example) The slope is about 2mm (0.08inch) as shown below.
Slope
Reference plane
-Rotate the Height Adjuster to +2.0 to reduce the door slope.
After adjustment, first tighten screw ( 3 ) and then screw ( 2 ).
PU 01ESTTING
Setting Up _15