INSTALLING OF THE WATER DISPENSER LINE
Connecting to water supply line
-Shut off the main water supply line and turn the Ice maker to the off position.
-Locate the nearest cold drinking water line.
-Follow the instructions in the ice maker installation kit.
1.Cold Water line
2.Pipe Clamp. 3.Copper (or Plastic) line 4.Compression Nut 5.Compression Sleeve 6.Shut Off Valve 7.Packing Nut.
Connect the water line to the refrigerator
1.Remove the cap from water line on the unit and insert compression nut to the water line on the unit after disassembling from provided water line.
2.Connect both water line from the unit and water line provided kit.
3.Tighten the compression nut onto the compression fitting. Be careful no gap between two items.
4.Turn water on and check for any leakage.
Loosen a
Remove |
cap |
Water Line |
from unit |
Water Line |
from Kit |
No gap |
Only connect the water line to a drinkable water source. If you have to repair or disassemble the NOTE water line, cut off 6.5mm of the plastic tubing to make sure you get a snug,
Before being used, the leakage in these places should be examined.
CAUTION
- Samsung Warranty does not cover |
|
WATER LINE INSTALLATION. |
|
- It’ll be done at customer’s charge except the |
|
retail price includes installation cost. | No Leak |
- Please contact Plumber or Authorized |
|
Installer for the installation if needed. |
|
-If Water leakage happened due to improper installation, Please contact installer.
Check the water supply line
Connect the water pipe with coupler and tap.
-Close the main water tap.
-Connect coupler “A” to the tap.
-Every join should be protected with sealing tape.
WARRANTY INFORMATION
This water line installation is not covered by the refrigerator or ice maker manufacturer's warranty. Follow these instructions carefully to minimise the risk of expensive water damage.
Note:
If the coupler does not fit on the current tap, go the nearest autho- rised service dealer and purchase the right couplers fittings.
CAUTION
The water line must be connect-
ed to the cold water pipe. If it is connected to the hot water pipe, it may cause the purifier to malfunction.
COUPLER “A”
TAP
28