How to use OSD Menu

COMMUNICATION

￿COMMUNICATION￿

RS-485

PROTOCOL SAMSUNG

BAUD RATE 9600

ADDRESS0

￿￿

The COMMUNICATION menu is used to configure the settings regarding RS-485 communications.

Use the rear panel of the camera to connect to RS-485.

SYSTEM INFORMATION

￿SYSTEM INFO￿

TYPE

3_BOX_NOR_N

PROTOCOL

SAMSUNG

ADDRESS

1

COMM. TYPE

RS-485,HALF

BAUD RATE

9600

SERIAL NO. 000000000000000

CAMERA VER.

0.50_090101

EEPROM VER.

0.50_090101

￿

￿

You can view the system information including the protocol, address, baud rate, serial number, camera version, and EEP version.

[Camera I/O Connector]

Use the ￿￿￿￿ switch to specify the protocol, baud rate and address (0~255) for communications.

PROTOCOLSelect a communication protocol.

BAUD RATE Select a baud rate.

Note :

The baud rate differs, depending on the specified protocol.
ADDRESS[0~255]

You must specify a unique address for each camera in the same RS-485 network.

To control a specific camera, you must match the address of the camera with that of the DVR or the controller.

LANGUAGE

￿LANGUAGE￿

￿ENGLISH

PУCCKNЙ

POLSKI

ČESKY

TÜRKÇE

￿￿

The camera supports 5 different languages. Select a preferred language.

26 – DIGITAL COLOR CAMERA