DAY/NIGHT External Signal Input & Alarm Signal Output

This is a function to receive the external DAY/NIGHT signal from the

Esensor(option) and convert the signal into BW. The MOTION DET function generates an alarm signal when a movement is detected.

DAY/NIGHT IN

GND

ALARM OUT

Connect an external sensor to the DAY/NIGHT terminal as shown in

then

connect any external device such as a buzzer or lamp to the ALARM

 

terminal as shown in

.

 

The ALARM output terminal is an open collector with the following capacity: DC 16V and 100mA.

OFF : Open contact

ON : Below 100mA

The DAY/NIGHT input terminal has the input of DC 5V pull-up and over 0.2mA.

OFF : Open contact

ON : Closed contact

Camera Operation Switch(Setup Switch)

The function of the camera operation switch changes depending on

whether the camera is currently in the usual operation mode(No setup

E

menu is seen on the screen) or the setup menu mode.

 

[LEFT/RIGHT] key

 

[UP/DOWN] key

 

[ENTER] key

In the usual operation mode

[LEFT/RIGHT] key : Press key for about 2 seconds and the

menu comes out to control the DC IRIS level. The [LEFT] key raises the level and the [RIGHT] key lowers the level.

[ENTER] key : It is used to enter the Setup menu.(Press it about 2 seconds.)

In the setup menu mode

[UP/DOWN] key : These keys move up or down the cursor.

[LEFT/RIGHT] key : These keys move the cursor to the left or right or identify the values sequentially which can be assigned in each setup menu.

[ENTER] key : It is used to enter a sub-menu of a setup menu by

clicking the setup menu or to set the current value.

Power Connection Port

This port is connected to the power(adapter) cable.

10